background image

AR

✴✴

FSSSBWK Series

AR

✴✴

FSSSCUR Series

Air Conditioner

user & installation manual

imagine 

the possibilities

Thank you for purchasing this Samsung product. 
To receive more complete service, please 
register your product at

www.samsung.com/register

This manual is made with 100% recycled paper.

AR

✴✴

JV5N

✴✴ 

 Series

AR

✴✴

KV5N

✴✴ 

 Series

Air Conditioner

user & installation manual

imagine 

the possibilities

Thank you for purchasing this Samsung product. 

NA_GOOD_A3050_IB&IM_EN_DB68-05202A-02.indd   1

11/6/2015   2:32:36 PM

Содержание AR JV5N Series

Страница 1: ...ct To receive more complete service please register your product at www samsung com register This manual is made with 100 recycled paper AR JV5N Series AR KV5N Series Air Conditioner user installation...

Страница 2: ...mfort cooling If you want the comfortable and refreshing air Comfort function will spread the cool air indirectly to you so that you can stay comfortable Single User Use Single User function when you...

Страница 3: ...31 Choosing the installation location 32 Accessories 35 Fixing the installation plate 36 Disassembling Assembling the Cover panel for indoor unit installation 38 Connecting the assembly cable 40 Insta...

Страница 4: ...e power line with the power specifications of the product or higher and use the power line for this appliance only In addition do not use an extension line Extending the power line may result in elect...

Страница 5: ...r problems with the product Install the draining hose properly so that water is drained correctly Failing to do so may result in water overflowing and property damage Avoid adding drain to waste pipes...

Страница 6: ...enter Failing to do so may result in problems with the product water leakage electric shock or fire A delivery service for the product is not provided If you reinstall the product in another location...

Страница 7: ...dren to climb onto the machine This may result in children seriously injuring themselves Do not use this air conditioner for long periods of time in badly ventilated locations or near infirm people Si...

Страница 8: ...e appliance with wet hands This may result in electric shock Do not spray volatile material such as insecticide onto the surface of the appliance As well as being harmful to humans it may also result...

Страница 9: ...ric shock or fire Before cleaning or performing maintenance cut off the power supply and wait until the fan stops Failing to do so may result in electric shock or fire FOR CLEANING CAUTION Take care w...

Страница 10: ...ng your air conditioner If the air conditioner operates in cooling mode for long period of time in high humidity area dew may be formed Mode Indoortemperature Outdoortemperature Indoorhumidity Cooling...

Страница 11: ...ame of the parts Display Power button Remote controller receiver Air filter Air flow blade upanddown Air flow blade leftandright Room temperature sensor Air intake Single user indicator Timer Auto cle...

Страница 12: ...ou may simply cancel it by pressing the SET button while selected item is blinking Power Turn on off the air conditioner Temp Increase Decrease the temperature by 1 C Options Select options during ope...

Страница 13: ...hear click sound when the cover is locked properly The signal may not be received properly if electronic flourescent lamps such as inverter flourescent lamps are operating in the same space If other e...

Страница 14: ...ctivate the Dry mode set temperature on the remote controller should be lower than indoor room temperature Fan Fan mode can be selected to circulate your room Fan mode will be helpful to refresh the s...

Страница 15: ...the set temperature by 1 C within the range of 16 C 30 C Dry You can adjust the set temperature by 1 C within the range of 18 C 30 C Fan Temperature adjustment is not possible Heat You can adjust the...

Страница 16: ...direction vertically Press the button to make air flow blades vertically Remote controller display f f To keep the air flow direction in a constant direction press the button again The air flow blade...

Страница 17: ...ndoor unit display Cancel f f Press the Timer button select On press the or button set the timer to press the SET button Additional options available in On Off timer mode When the remote controller is...

Страница 18: ...nit and the On Off status of the indicator on the remote controller display Only the latest setting timer will be applied between the OnTimer Off Timer and Off timer functions After setting the timer...

Страница 19: ...set the desired temperature by 1 C in the range of 16 C 30 C Fan speed will be adjusted automatically according to the mode However If you select mode while heating operation is on you can adjust fan...

Страница 20: ...tioner is operating in Cool mode Remote controller display 1 Press the Options button 2 Press the or Options button until 2 Step indicator starts to blink 3 Press the SET button to set the 2 Step Cool...

Страница 21: ...functionison correspondingfunctionwillbecancelled You can set the Fast function to provide fast and powerful cooling heating When the air conditioner is operating in Cool Heat mode Remote controller d...

Страница 22: ...on once again Single user function is only available in Cool Heat mode If theSingleuserfunctionisselectedwhile2 StepCooling Fast Comfort Quiet functionison correspondingfunctionwillbecancelled Vertica...

Страница 23: ...Quiet function will begin Cancel f f Press the Options button Press the or Options button to make the Quiet indicator blink and press the SET button Additional options available in Quiet function You...

Страница 24: ...Auto clean function Clean indicator on the remote controller display will disappear and Timer indicator will turn on the indoor unit display Auto clean function will be activated after the air conditi...

Страница 25: ...indoor unit heat exchanger because it needs to be disassembled Heatexchanger Illustration may differ slightly depending on the models Make sure to turn off the power of the indoor unit and cut off the...

Страница 26: ...by hand washing Remove the air filter from the main body Insert the air filter back in its original position Dry the Air filter in a ventilated area Clean the Air filter with a vacuum cleaner or soft...

Страница 27: ...of the Air filter into the main body Air filter 2 There s one hook in both side of the filter press the surface of the Air filter softly and get the hooks into the main body 3 Press the bottom of the...

Страница 28: ...rain pan 2 Thoroughly clean the heat exchanger 2 Clean the cross fan 2 Clean the condensate drain pipe 2 Replace the remote controller batteries 1 Outdoor unit Clean the heat exchanger on the outside...

Страница 29: ...thereisalotofdustonthe Airfilter cooling heating performancemaydecrease Cleanthem frequently Checkiftheoutdoorunitiscoveredorinstalledneartheobstacle Takethecoveroffandtaketheobstacleaway Checkiftheai...

Страница 30: ...dorspermeatein theroomduring operation Checkiftheapplianceisrunninginasmokyarea Ventilatethe roomoroperatetheairconditionerinFanmodefor1 2hours Wedonotusesmellycomponentsintheairconditioner ChecktheDr...

Страница 31: ...e Operating limits table included in the manual shall immediately invalidate the warranty The air conditioner should be used only for the applications for which it has been designed the indoor unit is...

Страница 32: ...the power supply is compliant with current safety standards Always install the air conditioner in compliance with current local safety standards Always verify that a suitable grounding connection is...

Страница 33: ...oil Salty environment such as seaside areas Where sulfide gas exists Other special atmosphere areas The appearance of the unit may be different from the diagram depending on the model Make at least on...

Страница 34: ...art of the outdoor unit and the air outlet is opposite the wall When the walls are blocking front and the rear side of the outdoor unit 300 or more 1500 or more Top view Side view Air outlet Air intak...

Страница 35: ...enerate sound and cause bad effect on the product Installation must be done in level and in a place where vibration will not cause any effect Accessories The following accessories are supplied with th...

Страница 36: ...x 4 m 1 12 Insulated Assembly Pipe 12 70 mm x 4 m 1 18 Insulated Assembly Pipe 15 88 mm x 4 m 1 24 PET3 FoamTube Insulation 1 VinylTapes 2 Putty 100 g 1 Pipe Clamps A 3 Pipe Clamps B 3 Cement Nails 6...

Страница 37: ...ots if there are less than two studs or the distance between the studs are different from the plate hanger Fix the installation plate without inclining to one side Make sure that a wall can withstand...

Страница 38: ...hat you can disassemble the cover panel Cap Screw Remove the Cap screw Unfasten the screw Cover Panel Removing the Cover panel Before mounting the indoor unit The bottom panel fits the main body using...

Страница 39: ...Assembling the Cover panel After mounting the indoor unit To assemble the Cover panel proceed in reverse order of disassembling Use both hands for assembling and be extra careful not to damage the pip...

Страница 40: ...rds of electrical installations and the the wiring regulations of the Local wiring regulations 2 Tighten the terminal block screw to 1 2 1 8 N m 12 18 kgf cm 3 Precautions when connecting terminal blo...

Страница 41: ...bles to extend the length It may cause fire When you install the unit make first refrigerant connections and then electrical connections Connect the air conditioner to grounding system before performi...

Страница 42: ...rocedure for the refrigerant pipe varies according to the exit position of the pipe when facing the wall Right A Left B Underside C Rear B A C Outer Diameter Torque N m kgf cm 6 35 mm 14 18 140 180 9...

Страница 43: ...heck if nitrogen gas flows out of indoor unit If this one isn t true DO NOT INSTALLTHE UNIT since leakage could be inside the indoor unit Unscrew the caps Pipes 1 Make sure that you have all the requi...

Страница 44: ...ble Tighten the flare nut with torque wrench according to specified method If the flare nut is over tightened the flare may break and cause refrigerant gas leakage Outer Diameter Torque N m kgf cm 6 3...

Страница 45: ...ose into Extended hose for 40 45 mm Make sure the two hoses are firmly connected to ensure that there is no water leakage 5 Connect the Drain Hose after using Foam Insulation to wrap the Extended Hose...

Страница 46: ...lectrical part Change the direction only when it is necessary 1 Detach the rubber cap with the pliers 2 Detach the drain hose by pulling it and turning to the right 3 Insert the drain hose by fixing i...

Страница 47: ...essive torque can be cause of gas leakage 3 Connect the charging hose of the low pressure side of manifold gauge to a gas service port as seen in the picture 4 Open the valve of the low pressure side...

Страница 48: ...ns of liquid When recharging refrigerant from the refrigerant cylinder to the equipment follow the instructions below 1 Before recharging check whether the cylinder has a siphon or not There are two w...

Страница 49: ...valve with the Allen wrench Turn the system on in cooling with fan operating at high velocity Compressor will immediately start provided 3 minutes have elapsed since the last stop After 2 minutes of o...

Страница 50: ...e outdoor unit as indicated on the top of the unit to let the discharged air out properly 2 Fix the outdoor unit in level to an appropriate support using anchor bolts 3 If the outdoor unit is exposed...

Страница 51: ...uired for pipe extension 2 Status of the indicator after supplying the power Standby status 2 When the air conditioner is in standby status use the remote controller to start the Smart Install mode 1...

Страница 52: ...indicator Error Measures to take by an installer Display LED Display LED 1 LED 2 LED 3 Communication Error between Indoor and outdoor unit 1 Check the connection wire between indoor and outdoor unit w...

Страница 53: ...taT Heating mode indoor unit check Outlet air temp Inlet air temp From 11 C to 14 C indicative deltaT In heating mode the indoor fan motor can remain off to avoid cold air blown into conditioned space...

Страница 54: ...tape twice and position your contraction tube in the middle of the insulation tape 5 Apply heat to the contraction tube to contract it 6 After tube contraction work is completed wrap it with the insu...

Страница 55: ...English 55 NA_GOOD_A3050_IB IM_EN_DB68 05202A 02 indd 55 11 6 2015 2 33 39 PM...

Страница 56: ...TRY CALL OR VISIT US ONLINE AT INDIA 1800 3000 8282 Toll Free 1800 266 8282 Toll Free www samsung com in support This product is RoHS compliant DB68 05202A 02 NA_GOOD_A3050_IB IM_EN_DB68 05202A 02 ind...