manualshive.com logo in svg
background image

FTXG25EVMAW FTXG25EVMAS

FTXG35EVMAW FTXG35EVMAS

MODELS

DAIKIN ROOM AIR CONDITIONER

Operation Manual

00_CV_3P166462-1.fm  Page 1  Monday, October 3, 2005  7:50 PM

Содержание FTXG25EVMAW

Страница 1: ...FTXG25EVMAW FTXG25EVMAS FTXG35EVMAW FTXG35EVMAS MODELS DAIKIN ROOM AIR CONDITIONER Operation Manual 00_CV_3P166462 1 fm Page 1 Monday October 3 2005 7 50 PM...

Страница 2: ...RATION AUTO DRY COOL HEAT FAN Operation 10 Adjusting the Air Flow Direction 12 POWERFUL Operation 14 OUTDOOR UNIT SILENT Operation 15 INTELLIGENT EYE Operation 16 TIMER Operation 18 CARE Care and Clea...

Страница 3: ...When carrying out repairs accompanying adding refrigerant check the content of the repairs with our service staff Do not attempt to install the air conditioner by your self Incorrect work will result...

Страница 4: ...es and other debris accumulate around the unit Leaves are a hotbed for small animals which can enter the unit Once in the unit such animals can cause malfunc tions smoke or fire when making contact wi...

Страница 5: ...4 Names of parts Indoor Unit 15 14 18 12 13 17 1 3 4 6 2 11 16 5 7 8 9 10 With the panel closed 01_EN_3P166462 1 fm Page 4 Tuesday September 20 2005 5 08 PM...

Страница 6: ...Room temperature sensor It senses the air temperature around the unit 14 Operation lamp green 15 TIMER lamp yellow page 18 16 INTELLIGENT EYE lamp green page 16 17 INTELLIGENT EYE sensor It detects th...

Страница 7: ...once again to stop it 7 MODE selector button It selects the operation mode AUTO DRY COOL HEAT FAN page 10 8 SILENT button OUTDOOR UNIT SILENT operation page 15 9 FAN setting button It selects the air...

Страница 8: ...acing once a year although if the remote controller display begins to fade or if reception deteriorates please replace with new alkali batteries Do not use manganese batteries The attached batteries a...

Страница 9: ...g on the power breaker will cause the panel and flap to open once and then close again This is a normal procedure CAUTION ATTENTION During operation i e when the panel is open or being opened or close...

Страница 10: ...conditioner for a long period for example in spring or autumn turn the breaker OFF Use the air conditioner in the following conditions Operation outside this humidity or temperature range may cause a...

Страница 11: ...uence AUTO DRY COOL HEAT FAN 2 Press ON OFF button The operation lamp will light up and the panel will open To stop operation 3 Press ON OFF button again The operation lamp will go off and the panel w...

Страница 12: ...y occur on the outdoor unit and lower the heating capacity In that case the system switches into defrosting operation to take away the frost During defrosting operation hot air does not flow out of in...

Страница 13: ...To adjust the vertical blades louvers 3 Press SWING button is displayed on the LCD 4 When the louvers have reached the desired position press the SWING button once more The louvers will stop moving To...

Страница 14: ...tends to collected at the bottom of the room and hot air which tends to collect near the ceiling throughout the room preventing areas of cold and hot developing Comfort Airflow The air flow is set au...

Страница 15: ...sed together with SILENT or COMFORT Operation Priority is given to the function of whichever button is pressed last This does not include SILENT operation POWERFUL Operation can only be set when the u...

Страница 16: ...n 2 Press SILENT button again NOTE Note on OUTDOOR UNIT SILENT operation This function is available in COOL HEAT and AUTO modes This is not available in FAN and DRY mode POWERFUL operation and OUTDOOR...

Страница 17: ...the INTELLIGENT EYE operation 2 Press SENSOR button again EX When somebody in the room Normal operation The INTELLIGENT EYE lamp lights up When nobody in the room 20 min after start energy saving oper...

Страница 18: ...The sensor also mistakenly detects pets sunlight fluttering curtains and light reflected off of mirrors as passersby INTELLIGENT EYE operation will not go on during powerful operation Night set mode...

Страница 19: ...he setting rapidly 3 Press OFF TIMER button again The TIMER lamp lights up To cancel the OFF TIMER operation 4 Press CANCEL button The TIMER lamp goes off NOTE When TIMER is set the present time is no...

Страница 20: ...pidly 3 Press ON TIMER button again The TIMER lamp lights up To cancel ON TIMER operation 4 Press CANCEL button The TIMER lamp goes off To combine ON TIMER and OFF TIMER A sample setting for combining...

Страница 21: ...g axes on either side of the front panel into the holes and slowly close Press either side of the front panel CAUTION Units Don t touch the metal parts of the indoor unit If you touch those parts this...

Страница 22: ...al detergent thinned with lukewarm water then dry them up in the shade It is recommended to clean the air filters every two weeks Titanium Apatite Photocatalytic Air Purifying Filter gray The Titanium...

Страница 23: ...ter contact to the service shop there you bought the air conditioner Dispose of old filters as burnable waste Check that the base stand and other fittings of the outdoor unit are not decayed or corrod...

Страница 24: ...on In COOL or DRY mode Moisture in the air condenses into water on the cool surface of outdoor unit piping and drips Mists come out of the indoor unit This happens when the air in the room is cooled i...

Страница 25: ...ere anything to block the air inlet or the outlet of the indoor and the outdoor units Clean the air filters or take all obstacles away and turn the breaker OFF Then turn it ON again and try operating...

Страница 26: ...seasons of use resulting in poor performance It is recommended to have periodical maintenance by a specialist aside from regular cleaning by the user For specialist maintenance contact the service sho...

Страница 27: ...26 MEMO 01_EN_3P166462 1 fm Page 26 Tuesday September 20 2005 5 08 PM...

Страница 28: ...27 MEMO 01_EN_3P166462 1 fm Page 27 Tuesday September 20 2005 5 08 PM...

Страница 29: ...28 MEMO 01_EN_3P166462 1 fm Page 28 Tuesday September 20 2005 5 08 PM...

Страница 30: ...0509 HT 3P166462 1 M05B042 00_CV_3P166462 1 fm Page 2 Monday October 3 2005 7 50 PM...

Отзывы: