![RS PRO 917-6298 Скачать руководство пользователя страница 88](http://html.mh-extra.com/html/rs-pro/917-6298/917-6298_instruction-manual_1496054088.webp)
IIT-2000/2010/5000/5010 Instruction Manual/English
86
05/08/2015 Version No. 001
Special MANU Test Mode (000)
Special Test
Mode Overview
When MANU number 000 is selected, the special test mode is
activated. Under the special test mode, the voltage can be
changed during a test, in real time (ACW, DCW only). The test
function can also be changed when in READY or VIEW status,
unlike under normal operation.
Separate settings can be saved under the special test mode
for each of the testing functions: ACW, DCW, IR and GB. This
means a different ACW, DCW, IR and GB test setup can be
saved for MANU number 000.
Sweep Function
Overview
The IIT-5000 and 5010 have access to the sweep mode
function. The sweep function creates a graph of one of the
ACW, DCW, IR or GB tests in the special manual mode. The
graph will plot the output voltage, current or resistance versus
time. After the test has been completed, the test current,
voltage or resistance at any point in time can be viewed in the
graph.
Below is an example of the resultant sweep plot of a DCW test
where a DC voltage is ramped up to a user-defined level until
the HI SET current level has been tripped or the test time runs
out.