CrossOver 16 User Manual (v4.0)
Advanced Operation • 4–7
Professional, or Windows 7, and the Windows
Explorer.
To create an FTP connection to your switcher
from Windows XP Professional, or Windows 7:
1.
On the taskbar, click that
Start
button.
2.
Select
All Programs > Accessories >
Windows Explorer
.
3.
In the Windows Explorer address bar, type
ftp://
<ip_addr>
• where
<ip_addr>
is the IP address of your
switcher).
4.
Enter the following when prompted for a user
name and password:
Note:
• The
user
and
xpression
accounts also have
access to the USB drive if one is plugged into your
switcher.
Live Edit Decision Lists (EDL)
Edit Decision Lists are files used by non-linear
editing (NLE) suites to aid in post-production. Your
switcher can capture EDL data in a file that you load
into your NLE suite.
Configuring Live EDL Behavior
You can configure your switcher to trigger multiple
GPI outputs at the start, end, or both of EDL data
capture. You can also set a pre-delay for each GPI
output. EDL data capture does not begin until the
highest pre-delay has passed. This is useful when the
switcher needs to wait for external equipment to
become ready. The example below shows the effects
of various triggering and pre-delay settings.
Figure 4.1 Live EDL Timeline
1.
EDL capture is manually started. GPI output 2 is
triggered.
2.
4 frames later, GPI output 1 is triggered.
3.
16 frames after EDL capture is manually
triggered, the switcher begins capturing EDL
data.
4.
EDL capture is manually stopped. GPI output 2
and 3 are triggered.
To configure Live EDL behavior:
1.
Press
MENU
.
2.
Press the
SYSTEM
Wipe Pattern button.
3.
Press
NEXT
until
LivEDL Config
is
displayed.
4.
Press the
LiveEDL Config
knob to display
the EDL Configuration menu.
5.
Use the
GPO
knob to select a GPI output.
You can choose from any GPI bank and pin that
has been configured as a GPI output.
6.
Use the
Triggr
knob to select when the GPI
output is triggered. You can choose from the
following:
•
Off
— The GPI output is not triggered.
•
Start
— The GPI output is triggered at the
start of EDL data capture.
•
Stop
— The GPI output is triggered at the
end of EDL data capture.
•
Both
— The GPI output is triggered at both
the start and end of EDL data capture.
7.
If you selected
Start
or
Both
in step 6, use the
PreDly
knob to specify the number of
frames the switcher delays after the GPI output
is triggered before EDL capture begins.
Note:
• If no GPI banks are configured as outputs, you can
not select s GPI output in step 5 above.
• If the selected GPI output is configured as a level
trigger, it remains in the latched state until you
unlatch it.
Table 4.2 FTP Account Information
User Name
Password
Account Type
xpressio
n
password
Use for accessing
Media-Store storage.
liveedl
password
Use for accessing Live
EDL storage.
user
password
General storage access
Table 4.3 Live EDL GPI Output Triggers
GPI
Output
Triggered On
Pre-Delay (Frames)
1
Start
12
2
Both
16
3
Stop
—
16
12
1
2
3
4
MENU
NEXT
Содержание CrossOver 16
Страница 1: ...Ross Video Limited CrossOver 16 Operator s Manual Software Issue 4 0...
Страница 10: ......
Страница 32: ...2 16 Configuration CrossOver 16 User Manual v4 0...
Страница 84: ...8 4 Calibration and Diagnostics CrossOver 16 User Manual v4 0...