Instrument Function
R&S
®
SMF100A
300
Operating Manual 1167.2319.02 ─ 12
The instrument displays the parameters required for configuring pulse train data.
4. Select "Pulse Train Data... > New List / Select List or File Manager".
5. Navigate to the target directory and select an existing file, or create a new file by
assigning the "File Name".
6. According to your selection, confirm with "Save" or "Select".
The R&S
SMF automatically uses the new file for further editing. Pulse train data
files have the fixed file extension
*.pulstrn
.
7. In the "Pulse Modulation" dialog, select "Edit Pulse Train Data... > Edit" to define
the on and off time value pairs and the repetition factor for each value pair.
8. When completed, save the file.
9. Starting in the block diagram, perform the following steps to activate signal genera-
tion:
a) Select "Mod Gen > config... > Pulse Generator > Video/Sync Signal State >
On".
b) Select "Modulation > config... > Pulse Modulation > State > On".
c) Activate RF signal generation in the "RF Frequency" block.
The R&S
SMF generates an RF pulse sequence signal according to the values
specified in the file.
Pulse Train Data – Pulse Generator
Opens the "File Select" dialog for selecting and creating a pulse train file, and provides
access to the "File Manager".
Remote command:
[:SOURce<hw>]:PULM:TRAin:CATalog?
[:SOURce<hw>]:PULM:TRAin:SELect
[:SOURce<hw>]:PULM:TRAin:DELete
Edit Pulse Train Data – Pulse Generator
.
Pulse Train Dialog
Modulation Generator, Pulse Generator and LF Output