![Rohde & Schwarz FSH13 Скачать руководство пользователя страница 293](http://html.mh-extra.com/html/rohde-and-schwarz/fsh13/fsh13_operating-manual_1477832293.webp)
R&S FSH
Digital Modulation Analyzer
Measurements on CDMA2000 Signals
Operating Manual 1173.6275.12 - 30
278
Sync Power Relative to <Reference>
Shows the power of the synchronization channel (SYNC) in relation to the pilot channel
or the RF channel power.
For more information see "
C<x> (Ch.SF) Relative to <Reference>
Shows the power of the currently selected code channel in relation to the pilot channel
or the RF channel power. The numbers in the C<x> element and the walsh code
(Ch.SF) depend on the currently selected channel.
For more information see "
9.5.2.2 Diagram Area
The Code Domain Power result display contains the measurement results in graphic
form. It shows the power of all codes in the signal. In the graph, each bar represents
one (Walsh) code.
The displayed codes have different colors. The color of the code depends on the state
of the channel it belongs to.
● Yellow: active code (channels)
● Turquoise: inactive (code channels)
The number of codes that are displayed depends on the base spreading factor. For
more information see "
Setting the Base Spreading Factor
The order the R&S FSH displays the codes in depends on the code order. For more
information see "
The power of the codes is a relative value. The reference power is either the total
power of the signal or the power of the pilot channel. For more information see
"