20
FAMILY CONDENS KIS - FAMILY CONDENS IS
FAMILY CONDENS KIS - Programmable parameters
* Output not available at present. * The value is expressed on the display in rpm/100 (e.g. 3700 = 37) W
ARNING: certain default values may be dif
ferent from those shown in the table, owing to the update level of the card.
N°
PAR
PARAMETER DESCRIPTION
UNIT OF
MEASUREMENT
MIN
MAX
DEFAULT
(factory set)
PARAM
set
via SAT
1
PARAMETER CAN NOT BE USED IN THIS MODEL, DO NOT MODIFY THE PROGRAMMING
1
2
INSIGNIFICANT PARAMETER
10 (10kW*)
16 (16kW)
20 (20kW*)
26 (25kW)
30 (30kW*)
34 (35kW)
50 (50kW*)
70 (70kW*)
26 (25kW)
34 (35kW)
3
DEGREE OF BUILDING INSULATION
min
5
20
5
10
DHW MODE
0 (OFF)
1 (instantaneous)
2 (not used)
3 (external storage tank with thermostat)
4 (external storage tank with probe)
5 (DS built-in storage tank)
6 (3S built-in storage tank)
1
11
MAXIMUM SET-POINT OF DHW CIRCUIT
°C
40
60
60
12
PARAMETER CAN NOT BE USED IN THIS MODEL, DO NOT MODIFY THE PROGRAMMING
60
13
PARAMETER CAN NOT BE USED IN THIS MODEL, DO NOT MODIFY THE PROGRAMMING
80
14
PARAMETER CAN NOT BE USED IN THIS MODEL, DO NOT MODIFY THE PROGRAMMING
5
20
HEATING MODE
0 (OFF)
1 (ON)
2 (
REMOTE PANEL + AREA VALVE)
3 (BAG
2
)
4 (NOT USED)
5 (NOT USED)
6 (BAG
2
MIX)
7 (NOT USED)
8 (NOT USED)
1
21
MAXIMUM HEATING SET-POINT
°C
40
80
80
22
MINIMUM HEATING SET-POINT
°C
20
39
20
23
MAXIMUM HEATING FAN SPEED
(Range Rated adjustment)
rpm
METHANE LPG
25kW 60(**) 60(**)
35kW 60(**) 59(**)
MAX
24
MINIMUM HEATING FAN SPEED
rpm
METHANE LPG
25kW 12(**) 19(**)
35kW 12(**) 19(**)
MIN
25
POSITIVE HEATING DIFFERENTIAL
°C
2
10
6
26
NEGATIVE HEATING DIFFERENTIAL
°C
2
10
6
28
DO NOT MODIFY THE PROGRAMMING
15
29
DO NOT MODIFY THE PROGRAMMING
5
30
DO NOT MODIFY THE PROGRAMMING
0
31
MAXIMUM HEATING SET-POINT 2CH (circuit 2)
°C
40
80
45
32
MINIMUM HEATING SET-POINT 2CH (circuit 2)
°C
20
39
25
40
TYPE OF DHW THERMOSTAT OPERATION
0 (OFF)
1 (AUTO)
2 (ON)
1
41
DHW Memory
0 (OFF)
1 (AUTO)
2 (ON)
1
42
H.T.C. FUNCTION
0 (OFF)
1 (AUTO)
1
43
HEATING MEMORY
0 (OFF)
1 (AUTO)
1
44
THERMOREGULATION FUNCTION
0 (OFF)
1 (AUTO)
1
45
THERMOREGULATION CURVE INCLINATION (OTC)
-
2.5
40
20
46
THERMOREGULATION FUNCTION 2CH
0 (OFF)
1 (AUTO)
1
47
THERMOREGULATION CURVE INCLINATION (OTC) 2CH
-
2.5
40
10
48
PARAMETER CAN NOT BE USED IN THIS MODEL, DO NOT MODIFY THE PROGRAMMING
-
50
TOUCH & GO FUNCTION
0 (OFF)
1 (ON)
1
51
HEAT REQUEST TYPE CH1 (circuit 1)
-
0
1
0
52
HEAT REQUEST TYPE CH2 (circuit 2)
-
0
1
0
61
ANTIFREEZE FUNCTION DHW TEMP. (ON)
°C
0
10
4
62
HEATING FUNCTION DELIVERY TEMP. (ON)
°C
0
10
6
63
PARAMETER CAN NOT BE USED IN THIS MODEL, DO NOT MODIFY THE PROGRAMMING
6
65
EXTERNAL PROBE REACTIVITY
0 (VERY FAST) 255 (VERY SLOW)
20
85
SEMI-AUTOMATIC CHARGE
0 (DISABLED)
1 (ENABLED)
1
86
PRESSURE OF SEMI-AUTOMATIC CHARGE (ON)
bar
0.4
1.0
0.6
87
PARAMETER CAN NOT BE USED IN THIS MODEL, DO NOT MODIFY THE PROGRAMMING
-
90
VARIABLE SPEED PUMP
-
0
100
41
92
ENABLING OF POST-CIRCULATION FROM DHW TO HEATING
-
0
1
0
93
DURATION OF POST-CIRCULATION FROM DHW TO HEATING
-
1
255
5
94
PUMP IN CONTINUOUS MODE ON FIRST CIRCUIT
-
0
1
0
95
PUMP IN CONTINUOUS MODE ON SECOND CIRCUIT
-
0
1
0
Содержание Family Condens 2.5 - 3.5 IS
Страница 101: ...101 HRVATSKI Sl 10 Sl 11 A A A B Sl 3 Sl 4 Sl 5 Sl 6 Sl 7 Sl 8 Sl 9 A Sl 12 Sl 13 Sl 15 Sl 14 Sl 16 Sl 17 Sl 18...
Страница 143: ...143 13 1 c N OFF RESET DHW IS DHW S DHW IS FAMILY N OFF KIS...
Страница 144: ...144 FAMILY CONDENS KIS FAMILY CONDENS IS 2 IS DHW IS DHW DHW IS DHW DHW IS DHW S DHW IS S SERVICE IS DHW S DHW c...
Страница 145: ...145 10 11 A A A B 3 4 5 6 7 8 9 A 12 13 15 14 16 17 18...
Страница 151: ...151 15 OFF 8 ENERGY FOR LIFE ENTER ESCAPE 21 10 3 PROG CODE ENTER ENTER A ENTER ENTER A ENTER ESCAPE ENTER ESCAPE 21...
Страница 189: ...189 SRPSKI Sl 10 Sl 11 A A A B Sl 3 Sl 4 Sl 5 Sl 6 Sl 7 Sl 8 Sl 9 A Sl 12 Sl 13 Sl 15 Sl 14 Sl 16 Sl 17 Sl 18...