17
ENGLISH
INF2 LIST
Note (*): if the DHW probe is faulty or disconnected, “- -” is displayed in place of the value.
Step
Description
Display 2
figu
res
Display 4
figures
1
Delivery probe temperature
xx
01
°C
2
Return probe temperature
xx
02
°C
3
First DHW probe temperature (*)
- storage tank with thermostat (mode A and B)
- storage tank with probe (mode C)
xx
03
°C
4
Not used on this model
xx
°C
5
Not used on this model
xx
05
6
Probe of second heating system
xx
06
°C
7
Not used on this model
xx
07
8
Fan speed/100
xx
xxxx
10-17
Alarms log
xx
HIS0-HIS7
18
Status of heat exchanger cleaning meter
bH
xxxx
14 - DISPLAY AND FAULT CODES
Faults
When a fault occurs the display will show a flashing code and the RESET
and
icons will appear simultaneously or not (Fig. 19). For a description
of the faults, refer to the table in the following page.
Resetting the faults
Wait about 10 seconds before resetting normal operating conditions,
then proceed as follows:
1) Visualisation of the icon only
The appearance of the
indicates that an operating fault has been diag
-
nosed, and the boiler is attempting to resolve it autonomously (temporary stop).
If the boiler does not resume normal operation, the display will show one of
the following two modes:
mode A
disappears, and the RESET icon appears along with a different alarm
code.
In this case, proceed as described in point 2.
mode B
the RESET icon will appear along with a different alarm code, together with
the .
In this case, proceed as described in point 3.
mode C
together with the , alarm code 91 will appear (see description below).
The intervention of the Technical Assistance Service is required.
The boiler is equipped with an auto-diagnostic system which, based on the
total number of hours in certain operating conditions, can signal the need to
clean the primary exchanger (alarm code 91).
Once the cleaning operation has been completed, reset to zero the total
hour meter with special kit supplied as an accessory following procedure
indicated below:
- Switch off the power supply
- Remove the electric casing by means of the screws and fixing hooks
- Extract the connector J13 (see wiring diagram)
- Power up the boiler and wait for alarm 13 to appear on the display
- Disconnect the power supply and reconnect connector J13
- Refit the electric casing and restore the boiler's function.
Note: the meter resetting procedure should be carried out after each in-
depth cleaning of the primary exchanger or if this latter is replaced.
2) Display of the RESET icon only
Press the
key to restore operation. If the boiler ignites and resumes
normal operation, the stop can be attributed to a random situation.
If the shutdown occurs again, contact the Technical Assistance Serv
-
ice.
MODE A
temporary
fault
definitive
fault
MODE B
temporary
fault
definitive
fault
Fig.19
Fig.20
Содержание Family Condens 2.5 - 3.5 IS
Страница 101: ...101 HRVATSKI Sl 10 Sl 11 A A A B Sl 3 Sl 4 Sl 5 Sl 6 Sl 7 Sl 8 Sl 9 A Sl 12 Sl 13 Sl 15 Sl 14 Sl 16 Sl 17 Sl 18...
Страница 143: ...143 13 1 c N OFF RESET DHW IS DHW S DHW IS FAMILY N OFF KIS...
Страница 144: ...144 FAMILY CONDENS KIS FAMILY CONDENS IS 2 IS DHW IS DHW DHW IS DHW DHW IS DHW S DHW IS S SERVICE IS DHW S DHW c...
Страница 145: ...145 10 11 A A A B 3 4 5 6 7 8 9 A 12 13 15 14 16 17 18...
Страница 151: ...151 15 OFF 8 ENERGY FOR LIFE ENTER ESCAPE 21 10 3 PROG CODE ENTER ENTER A ENTER ENTER A ENTER ESCAPE ENTER ESCAPE 21...
Страница 189: ...189 SRPSKI Sl 10 Sl 11 A A A B Sl 3 Sl 4 Sl 5 Sl 6 Sl 7 Sl 8 Sl 9 A Sl 12 Sl 13 Sl 15 Sl 14 Sl 16 Sl 17 Sl 18...