175
ROMÂNĂ
FAMILY CONDENS IS - Parametri programabili
* * Putere neutilizabilă momentan. ** V
aloarea este exprimată pe display în g/min/100 (exemplu 3700=37)
ATTENȚIE: anumite valori default pot fi diferite de cele indicate în tabel, ca urmare a nivelului de actualizare a plăcii electronice.
N°
PAR
DESCRIERE PARAMETRI
UNITATE
DE MĂSURĂ
MIN
MAX
DEFAULT
(SETAT DIN
FABRICĂ)
PARAM
SETAȚI DE CSA
1
PARAMETRU NEUTILIZABIL LA ACEST MODEL, NU MODIFICAȚI PROGRAMAREA
1
2
PARAMETRU FĂRĂ INFLUENȚĂ
10 (10kW*)
16 (16kW)
20 (20kW*)
26 (25kW)
30 (30kW*)
34 (35kW)
50 (50kW*)
70 (70kW*)
26 (25kW)
34 (35kW)
3
GRAD DE IZOLAȚIE A CLĂDIRII
min
5
20
5
10
MODALITATE ACM
0 (OFF)
1 (instantanee)
2 (neutilizat)
3 (boiler extern cu termostat)
4 (boiler extern cu sondă)
5 (boiler integrat DS)
6 (boiler integrat 3S)
3
11
MAXIM PUNCT SETAT CIRCUIT ACM
°C
40
60
60
12
MAXIM PUNCT SETAT ACM BOILER
°C
40
80
60
13
TEMPERATURĂ TUR BOILER EXTERN
°C
50
85
80
14
DELTA BOILER EXTERN (ON)
°C
0
10
5
20
MODALITATE ÎNCĂLZIRE
0 (OFF)
1 (ON)
2 (PANOU LA DISTANȚĂ + VALVE DE ZONĂ)
3 (BAG2)
4 (NEUTILIZAT)
5 (NEUTILIZAT)
6 (BAG2 MIX)
7 (NEUTILIZAT)
8 (NEUTILIZAT)
1
21
MAXIM PUNCT SETAT ÎNCĂLZIRE
°C
40
80
80
22
MINIM PUNCT SETAT ÎNCĂLZIRE
°C
20
39
20
23
VITEZĂ MAXIMĂ VENTILATOR ÎNCĂLZIRE
(reglare Range Rated)
g/min
METAN GPL
25kW 60(**) 60(**)
35kW 60(**) 59(**)
MAX
24
VITEZĂ MINIMĂ VENTILATOR ÎNCĂLZIRE
g/min
METAN GPL
25kW 12(**) 19(**)
35kW 12(**) 19(**)
MIN
25
DIFERENȚIAL ÎNCĂLZIRE POZITIV
°C
2
10
6
26
DIFERENȚIAL ÎNCĂLZIRE NEGATIV
°C
2
10
6
28
NU MODIFICAȚI PROGRAMAREA
15
29
NU MODIFICAȚI PROGRAMAREA
5
30
NU MODIFICAȚI PROGRAMAREA
0
31
MAXIM PUNCT SETAT ÎNCĂLZIRE 2CH (circuit II)
°C
40
80
45
32
MINIM PUNCT SETAT ÎNCĂLZIRE 2CH (circuit II)
°C
20
39
25
40
TIP FUNCȚIONARE TERMOSTAT ACM
0 (OFF)
1 (AUTO)
2 (ON)
1
41
MEMORY ACM
0 (OFF)
1 (AUTO)
2 (ON)
1
42
FUNCȚIONARE C.T.R.
0 (OFF)
1 (AUTO)
1
43
MEMORY ÎNCĂLZIRE
0 (OFF)
1 (AUTO)
1
44
FUNCȚIE DE TERMOREGLARE
0 (OFF)
1 (AUTO)
1
45
ÎNCLINAȚIE CURBĂ DE TERMOREGLARE (OTC)
-
2.5
40
20
46
FUNCȚIE DE TERMOREGLARE 2CH
0 (OFF)
1 (AUTO)
1
47
ÎNCLINAȚIE CURBĂ DE TERMOREGLARE (OTC) 2CH
-
2.5
40
10
48
PARAMETRU NEUTILIZABIL LA ACEST MODEL, NU MODIFICAȚI PROGRAMAREA
-
50
FUNCȚIE TOUCH & GO
0 (OFF)
1 (ON)
1
51
TIP CERERE DE CĂLDURĂ CH1 (circuit I)
-
0
1
0
52
TIP CERERE DE CĂLDURĂ CH2 (circuit II)
-
0
1
0
61
TEMPER. ACM FUNCȚ. ANTI-ÎNGHEȚ ACM (ON)
°C
0
10
4
62
TEMPER. TUR FUNCȚIONARE ÎNCĂLZIRE (ON)
°C
0
10
6
63
PARAMETRU NEUTILIZABIL LA ACEST MODEL, NU MODIFICAȚI PROGRAMAREA
6
65
REACTIVITATE SONDĂ EXTERNĂ
0 (FOARTE REPEDE) 255 (FOARTE ÎNCET)
20
85
UMPLERE SEMIAUTOMATĂ
0 (DEZACTIVARE)
1 (ACTIVARE)
0
86
PRESIUNE DE UMPLERE SEMIAUTOMATĂ (ON)
bar
0.4
1.0
0.6
87
PARAMETRU NEUTILIZABIL LA ACEST MODEL, NU MODIFICAȚI PROGRAMAREA
0
90
POMPĂ LA VITEZĂ VARIABILĂ
-
0
100
41
92
ABILITARE POST-CIRCULAȚIE DE LA ACM LA ÎNCĂLZIRE
-
0
1
0
93
DURATĂ POST-CIRCULAȚIE DE LA ACM LA ÎNCĂLZIRE
-
1
255
5
94
POMPĂ ÎN FUNCȚ. CONTINUĂ PRIMUL CIRCUIT
-
0
1
0
95
POMPĂ ÎN FUNCȚ. CONTINUĂ AL DOILEA CIRCUIT
-
0
1
0
Содержание Family Condens 2.5 - 3.5 IS
Страница 101: ...101 HRVATSKI Sl 10 Sl 11 A A A B Sl 3 Sl 4 Sl 5 Sl 6 Sl 7 Sl 8 Sl 9 A Sl 12 Sl 13 Sl 15 Sl 14 Sl 16 Sl 17 Sl 18...
Страница 143: ...143 13 1 c N OFF RESET DHW IS DHW S DHW IS FAMILY N OFF KIS...
Страница 144: ...144 FAMILY CONDENS KIS FAMILY CONDENS IS 2 IS DHW IS DHW DHW IS DHW DHW IS DHW S DHW IS S SERVICE IS DHW S DHW c...
Страница 145: ...145 10 11 A A A B 3 4 5 6 7 8 9 A 12 13 15 14 16 17 18...
Страница 151: ...151 15 OFF 8 ENERGY FOR LIFE ENTER ESCAPE 21 10 3 PROG CODE ENTER ENTER A ENTER ENTER A ENTER ESCAPE ENTER ESCAPE 21...
Страница 189: ...189 SRPSKI Sl 10 Sl 11 A A A B Sl 3 Sl 4 Sl 5 Sl 6 Sl 7 Sl 8 Sl 9 A Sl 12 Sl 13 Sl 15 Sl 14 Sl 16 Sl 17 Sl 18...