15
ENGLISH
TOUCH & GO
If you do not want to leave the memory function always on, or if you need
hot water straight away outside the memorised uses, the domestic hot wa
-
ter can be preheated just a short while before the demand.
Thanks to the Touch & Go function, the pre-heating function is instantly
activated when the tap is opened and closed, and prepares hot water only
for this single request.
INTELLIGENT SYSTEM FILLING
When the measured pressure drops below the alarm level the icon
lights
and the system filling key is activated.
The Intelligent system filling function is activated by pressing the key
(Fig. 12). After pressing the key the performance of the cycle is displayed
by the droplet icon that fills bit by bit
.
The droplet switches off when the filling cycle is complete.
Note
If the system filling pressure value drops below a minimum safety value,
fault 40 is displayed (see Chapter Faults). Press
to reset and to
subsequently activate the system filling procedure.
INFO
information concerning the condition of the boiler can be viewed by press
-
ing key : The wording INFO is displayed.
By turning the encoder A (Fig. 13) the following information is displayed in
sequence. The function is automatically closed if the key is not pressed
within 10 seconds.
Info list
Info 1
when connected to external probe, displays the external tem-
perature detected by the probe (Fig. 14)
Info 2
displays the system pressure value along with the filling symbol
(Fig. 15)
Info 3
displays the heating temperature set or calculated by the sys
-
tem (Fig. 16)
Info 4
displays the DHW temperature set (Fig. 17)
Info 5
displays the set heating temperature on the second circuit, only
if this is connected (fig. 18)
INFO 2
information that may be useful to the Technical Assistance Service can be
displayed by pressing and holding the key for 10 seconds: the wording
INF2 is displayed. The next set of information is displayed each time the
key is pressed.
INF2 LIST
Note (*): if the DHW probe is faulty or disconnected, “- -” is displayed in place of the value.
(***): if the flow-rate > 10 l/min, on the display will appear A.x l/min where A=10 - B=11 - C=12
Step
Description
Display 2
figu
res
Display 4
figures
1
Delivery probe temperature
xx
01
°C
2
Return probe temperature
xx
02
°C
3
First DHW probe temperature (*)
xx
03
°C
4
Not used on this model
xx
°C
5
Not used on this model
xx
05
6
Probe of second heating system
xx
06
°C
7
DHW flow-rate (***)
xx
07
l/min
8
Fan speed/100
xx
xxxx
10-17
Alarms log
xx
HIS0-HIS7
18
Status of heat exchanger cleaning meter bH
xxxx
Содержание Family Condens 2.5 - 3.5 IS
Страница 101: ...101 HRVATSKI Sl 10 Sl 11 A A A B Sl 3 Sl 4 Sl 5 Sl 6 Sl 7 Sl 8 Sl 9 A Sl 12 Sl 13 Sl 15 Sl 14 Sl 16 Sl 17 Sl 18...
Страница 143: ...143 13 1 c N OFF RESET DHW IS DHW S DHW IS FAMILY N OFF KIS...
Страница 144: ...144 FAMILY CONDENS KIS FAMILY CONDENS IS 2 IS DHW IS DHW DHW IS DHW DHW IS DHW S DHW IS S SERVICE IS DHW S DHW c...
Страница 145: ...145 10 11 A A A B 3 4 5 6 7 8 9 A 12 13 15 14 16 17 18...
Страница 151: ...151 15 OFF 8 ENERGY FOR LIFE ENTER ESCAPE 21 10 3 PROG CODE ENTER ENTER A ENTER ENTER A ENTER ESCAPE ENTER ESCAPE 21...
Страница 189: ...189 SRPSKI Sl 10 Sl 11 A A A B Sl 3 Sl 4 Sl 5 Sl 6 Sl 7 Sl 8 Sl 9 A Sl 12 Sl 13 Sl 15 Sl 14 Sl 16 Sl 17 Sl 18...