Users Instructions For C90 

and C110 Models

The Gas Safety (Installation And Use) Regulations: 1996 (as amended) 

impose certain statutory

obligations on gas users. Further information regarding these regulations can be obtained from your
Gas Supplier.

All gas appliances must be installed by competent persons by law in accordance with these
regulations. Membership of CORGI is indication of such a competent person with regard to gas
installation.

It is in your interests, and that of safety, to ensure that the appliance is installed correctly and that the
law is complied with. Failure to do so could lead to a hazardous &/or potentially dangerous situation.

Introduction

These instructions should be carefully read to ensure safe and economical
use of your boiler.
The Keston C90 and C110 are high efficiency central heating condensing
boilers designed to provide central heating and indirect sanitary hot water
supply. They are designed for use with fully pumped systems only. The C90
and C110 models are supplied for natural gas use only.

Servicing

To ensure continual safe and efficient operation of the boiler it is
recommended that the appliance be checked and serviced as necessary at
regular intervals. Generally once per year will be sufficient. It is the law that
any servicing must be carried out by a competent person.
NB:

There are no user serviceable parts inside the boiler cabinet. The
cabinet should only be removed by a qualified competent person.

Clearances

If fixtures are to positioned close to the boiler the following minimum
clearances must be observed: Top : 350 mm, Bottom : 150 mm, Left : 25 mm,

WD356/0/2003

page  i

Содержание C110

Страница 1: ...o ensure safe and economical use of your boiler The Keston C90 and C110 are high efficiency central heating condensing boilers designed to provide central heating and indirect sanitary hot water supply They are designed for use with fully pumped systems only The C90 and C110 models are supplied for natural gas use only Servicing To ensure continual safe and efficient operation of the boiler it is ...

Страница 2: ...your installer to advise whether your boiler serves one or two zones To set thermostat temperatures you must turn the relevant knob to the required position As you turn the knob both the displays one for each module will change to either c nn or d nn depending on the knob being turned As the knob is turned the required temperature the last two digits of the displays change Set the knob to the posi...

Страница 3: ...d 7 nn Module at end of heat request from zone 1 8 nn Module at end of heat request from zone 2 A nn Temporary mode whilst module adjusts its internal settings 9 nn Module off due to unexpected problem The module will attempt to re fire from this mode In this mode the display will alternately flash 9 nn and b xx where the xx has the following meaning b 18 Module ran too hot 95O C flow temperature ...

Страница 4: ...wn or flue overheat thermostat activated E 12 Internal electronics error rest or replace control box E 11 Power has been reset whilst module was in lockout E 04 Gas valve faulty or not connected E 03 No ignition after restart Check gas supply gas valve operation ignitor electrode spark generation E 02 Flame detected when not expected Check module earth and probe condition E 00 Description of fault...

Отзывы: