Right : 25 mm & Front : 305 mm. Extended clearance is required to the front
to allow for access for servicing.

Cleaning

Normal casing cleaning only requires dusting with a dry cloth. To remove
more stubborn marks wipe with a damp cloth and finish with a dry cloth.

Boiler Setup

1)

Check that the gas supply from the gas meter is turned ON

2)

Switch on the electric supply to the boiler and controls and set the heating
controls to call for heat. 

To Light The Boiler

The C90 and C110 boilers incorporate dual thermostats to allow two different zones
to be connected to operate at two different temperatures. Generally the central
heating zone is connected to zone 1 and the DHW calorifier to zone 2. You should
ask your installer to advise whether your boiler serves one or two zones.

To set thermostat temperatures you must turn the relevant knob to the required
position. As you turn the knob both the displays, one for each module, will change to
either “c nn” or “d nn”, depending on the knob being turned. As the knob is turned the
required temperature (the last two digits of the displays) change. Set the knob to the
position which gives the required temperature. When the knob is released the
display, after a few seconds, will return to normal.

If the boiler detects whether zone requires heat the following sequence will occur:
1)

The fan and pump will start inside the module and the displays will indicate “1
nn” to show the boiler modules have started the first stage of the ignition
sequence.

2)

After 5 seconds the displays will change to “2 nn” to indicate the spark ignition
of the sequence has started.

WD356/0/2003

page  ii

Содержание C110

Страница 1: ...o ensure safe and economical use of your boiler The Keston C90 and C110 are high efficiency central heating condensing boilers designed to provide central heating and indirect sanitary hot water supply They are designed for use with fully pumped systems only The C90 and C110 models are supplied for natural gas use only Servicing To ensure continual safe and efficient operation of the boiler it is ...

Страница 2: ...your installer to advise whether your boiler serves one or two zones To set thermostat temperatures you must turn the relevant knob to the required position As you turn the knob both the displays one for each module will change to either c nn or d nn depending on the knob being turned As the knob is turned the required temperature the last two digits of the displays change Set the knob to the posi...

Страница 3: ...d 7 nn Module at end of heat request from zone 1 8 nn Module at end of heat request from zone 2 A nn Temporary mode whilst module adjusts its internal settings 9 nn Module off due to unexpected problem The module will attempt to re fire from this mode In this mode the display will alternately flash 9 nn and b xx where the xx has the following meaning b 18 Module ran too hot 95O C flow temperature ...

Страница 4: ...wn or flue overheat thermostat activated E 12 Internal electronics error rest or replace control box E 11 Power has been reset whilst module was in lockout E 04 Gas valve faulty or not connected E 03 No ignition after restart Check gas supply gas valve operation ignitor electrode spark generation E 02 Flame detected when not expected Check module earth and probe condition E 00 Description of fault...

Отзывы: