CHAPTER 31 ELECTRICAL SPECIFICATIONS
Page 867 of 920
(Notes and Remarks are listed on the next page.)
(2/2)
Parameter Symbo
l
Conditions
MIN.
TYP.
MAX.
Unit
Supply
current
I
DD2
HALT mode HS (high-speed
main) mode
f
IH
V
DD
= 3.0 V
0.5
2.63
mA
f
IH
V
DD
= 3.0 V
0.42
2.03
f
IH
V
DD
= 3.0 V
0.39
1.50
LS (low-speed
main) mode
fIH = 8 MHz
V
DD
= 3.0 V
270
800
μ
A
V
DD
= 2.0 V
270
800
HS (high-speed
main) mode
f
MX
= 20 MHz
,
V
DD
= 3.0 V
Square wave
input
0.31
1.69
mA
Resonator
connection
0.41
1.91
f
MX
V
DD
= 3.0 V
Square wave
input
0.16
0.94
Resonator
connection
0.21
1.02
LS (low-speed
main) mode
f
MX
V
DD
= 3.0 V
Square wave
input
110
610
μ
A
Resonator
connection
150
660
f
MX
V
DD
= 2.0 V
Square wave
input
110
610
Resonator
connection
150
660
Subsystem clock
operation
fSUB = 32.768 kHz
T
A
=
‒
40
°
C
Square wave
input
0.31
μ
A
Resonator
connection
0.50
fSUB = 32.768 kHz
T
A
= +25
°
C
Square wave
input
0.38
0.76
Resonator
connection
0.57 0.95
fSUB = 32.768 kHz
T
A
= +50
°
C
Square wave
input
0.47
3.59
Resonator
connection
0.70 3.78
fSUB = 32.768 kHz
T
A
= +70
°
C
Square wave
input
0.80
6.20
Resonator
connection
1.00
6.39
fSUB = 32.768 kHz
T
A
= +85
°
C
Square wave
input
1.65
10.56
Resonator
connection
1.84
10.75
IDD3
STOP mode
T
A
=
‒
40
°
C
0.19
μ
A
T
A
= +25
°
C
0.30
0.59
T
A
= +50
°
C
0.41
3.42
T
A
= +70
°
C
0.80
6.03
T
A
= +85
°
C
1.53
10.39
Содержание RL78/G1H