CHAPTER 31 ELECTRICAL SPECIFICATIONS
Page 897 of 920
31.6.4
Power supply voltage rising slope characteristics
Caution
Make sure to keep the internal reset state by the LVD circuit or an external reset until V
DD
reaches the operating
voltage range shown in 31.4 AC Characteristics.
(2) Interrupt & Reset Mode
(T
A
=
‒
40 to +85
°
C, V
PDR
≤
V
DD
≤
3.6 V, V
SS
= 0 V)
Parameter
Symbol
Conditions
MIN.
TYP.
MAX.
Unit
Voltage detection
threshold
V
LVDB0
V
POC2
, V
POC1
, V
POC0
= 0, 0, 1, falling reset voltage
1.80
1.84
1.87
V
V
LVDB1
LVIS1, LVIS0 = 1, 0
Rising release reset voltage
1.94
1.98
2.02
V
Falling interrupt voltage
1.90
1.94
1.98
V
V
LVDB2
LVIS1, LVIS0 = 0, 1
Rising release reset voltage
2.05
2.09
2.13
V
Falling interrupt voltage
2.00
2.04
2.08
V
V
LVDB3
LVIS1, LVIS0 = 0, 0
Rising release reset voltage
3.07
3.13
3.19
V
Falling interrupt voltage
3.00
3.06
3.12
V
V
LVDC0
V
POC2
, V
POC1
, V
POC0
= 0, 1, 0, falling reset voltage
2.40
2.45
2.50
V
V
LVDC1
LVIS1, LVIS0 = 1, 0
Rising release reset voltage
2.56
2.61
2.66
V
Falling interrupt voltage
2.50
2.55
2.60
V
V
LVDC2
LVIS1, LVIS0 = 0, 1
Rising release reset voltage
2.66
2.71
2.76
V
Falling interrupt voltage
2.60
2.65
2.70
V
V
LVDD0
V
POC2
, V
POC1
, V
POC0
= 0, 1, 1, falling reset voltage
2.70
2.75
2.81
V
V
LVDD1
LVIS1, LVIS0 = 1, 0
Rising release reset voltage
2.86
2.92
2.97
V
Falling interrupt voltage
2.80
2.86
2.91
V
V
LVDD2
LVIS1, LVIS0 = 0, 1
Rising release reset voltage
2.96
3.02
3.08
V
Falling interrupt voltage
2.90
2.96
3.02
V
(T
A
=
‒
40 to +85
°
C, V
SS
= 0 V)
Parameter
Symbol
Conditions
MIN.
TYP.
MAX.
Unit
Power supply voltage rising slope
S
VDD
54
V/ms
Содержание RL78/G1H