Interfaces, Controls and Displays
Interfaces on the Rear Side
REGATRON
Performance. Precision. Quality.
TC.ACS - Device Manual (V04.60) - 26.4.2022
21 / 66
3.2.2 Integrated Safety Relay (TC.ISR)
3.2.2.1 Range of Application
The integrated safety relay TC.ISR allows for connecting an external safety circuit. Here, the external safety circuit
can be connected to the interface
X112-2
(see
).
3.2.2.2 General Function Description
When the TC.ISR is triggered it disconnects the power electronics of the TC device from its controller electronics.
This way the energy flow is interrupted while the device remains accessible for communication.
3.2.2.3 Type of Connection
Fig. 4:
Type of connection of interface X112-2: D-Sub, 9-pin, socket
As the TC.ISR operates on two channels, performance level PL e can be reached.
If the TC.ISR is not used, the interface
X112-2
must be terminated with the related dummy plug
(see
).