Option: TC.ACS.CANmp Interface
Configuration of a CAN Protocol
REGATRON
Performance. Precision. Quality.
TC.ACS - Device Manual (V04.60) - 26.4.2022
65 / 66
66
12.5.4.2 Definition of RX Signals
ActMeanValuePhaseCurrentGrid
Actual mean phase current [Arms] AC grid
Sint16, Sint32:
All signal
factors
Float32:
Signal factor 1
ActApparentPowerGrid
Actual apparent power [VA] AC grid
ActActivePowerGrid
Actual active power [W] AC grid
ActReactivePowerGrid
Actual reactive power [var] AC grid
ActPowerFactorGrid
Actual power factor AC grid
ActCANmpInterfaceVersion
Version of the CANmp interface
Uint16:
Signal factor 1
Signal name
Description
Configurable
data types /
signal factors
SetSyncSignal
A message containing this signal must be received by the TC.ACS
in order to send the Sync and SyncID messages.
Bit 0: Sync signal for sync messages
Bit 1: SyncID signal for syncID messages
Bit 2–15: SyncID for syncID messages
Uint16:
Signal factor 1
SetCommand
Set TC.ACS command
(0 = none, 1 = run, 2 = stop, 3 = discharge,
4 = clear error, 99 = reset)
SetSynchronisation
Enable Synchronous Mode only possible if TC.ACS is stopped.
Disable Synchronous Mode is always possible.
Bit 0: Phase A (L1)
Bit 1: Phase B (L2)
Bit 2: Phase C (L3)
SetFuncGenCommand
Set Waveform Generator command
(0 = none, 1 = stop, 2 = start, 3 = discontinue, 4 = continue, 5 =
pause, 6 = resume, 7 = block change,
99 = Reset Waveform Generator configuration)
SetFuncGenCreateBlock
Add a new Waveform Generator block. Up to 10 blocks can be
added. The signal value sets the block repetitions (0 = endless
repetitions (endless block))
SetFuncGenPhaseNo
Select phase number
(0 = phase A (L1), 1 = phase B (L2), 2 = phase C (L3), 3 = phase D
(N))
SetFuncGenFunctionType
Set the basic waveform of the currently selected phase
(0 = None, 1 = Sine, 2 = Exponential wave, 3 = DC, 4 = Saw tooth
down, 5 = Saw tooth up, 6 = Square wave, 7 = Triangle)
SetFuncGenPhaseAngle
Set phase angle [°] of currently selected phase
Sint16, Sint32:
All signal factors
Float32:
Signal factor 1
SetFuncGenFrequency
Set frequency [Hz] of currently selected phase
SetFuncGenAmplitude
Set amplitude of currently selected phase Û [V] or Î [A] depending
on controller mode
Signal name
Description
Configurable
data types /
signal factors