NEW OUTPUT OF ZONE
Setting the new zone output:
(From the “ZONE Configuration” window by pressing the PRG button, you enter
this window)
Identification of the new output assigned to the zone just configured:
Example: AREA <03> New Output: Wi-Z11- R1
It shows that the temperature input of the Zone 03 turns on the output on
Z11-R1 expansion unit.
ZONE <03>
──────────────────────
New Output:
---
SETTINGS / ZONES / DEHUMIDIFIER
DEHUMIDIFICATION PARAMETERS
Modify the dehumidification parameters
On the Dehumidifiers section the following submenus can be accessed:
Tipe: Type of dehumidifier
Air Quality type: Configuring air quality sensor
Configure Ux: Dehumidifier configuration
Configure Exp U: Exp U configuration
Integration: Integration for Ux-xx unit or Wi-UXY AHU expansion units
<MT>Deumidifiers
──────────────────────
Type: *
Air quality type: *
Configure UxBUS : *
Configure Exp U: *
Integration: *
──────────────────────
ZONES \ DEHUMIDIFIER \
TY
PE
SETTINGS / ZONES / DEHUMIDIFIER / TYPE
TYPE OF DEHUMIDIFIER
Modify the type of dehumidifier:
Type: Dehumidifier version (*)
ExpD: It identifies which expansion unit receives the dehumidification input
SysPmp: It identifies the pump hydraulic connection
Alarm: It enables the dehumidifier alarm
(*) If the dehumidifier type = Deum D + I, the software will also display:
ExpI: It identifies which expansion unit receives the integration input
En.Win: It enables winter sensible heat integration
En.Sum: It enables summer sensible heat integration
Diff: Room differential/set to enable relevant operation
If the dehumidifier type = Deum D + V + R, the software will also display:
All.zone D: identifies which kind of operation shall be carried out on the dehumidification
control in the area in case of dehumidifier alarm.
T: identifies which kind of operation shall be carried out on the temperature control in
the area in case of dehumidifier alarm.
If the dehumidifier type = Deum D + R, the software will also display:
ExpR: identifies the output for the fresh ventilation control in the Wi-Z expansion unit.
TMR: identifies which kind of schedule timer for the fresh air ventilation in the AHU.
ZONE 1
›››
ZONE 64
ZONE 2 S.Dehu 02
──────────────────────
Type:Deum D + I
ExpD:---
SysPmp:No Alarm:No
Exp I:---
En.Win:Si Diff.:01.0.c
En.Sum:No Diff.:02.0.c