User realm
Text {must contain at least one dot “.”}
Realm allows to shorten the login name - e.g. when the full login name is "[email protected]" and
the realm is "noname.eu" the Username filled in the login page is only "tech".
Server response timeout [s]
Number {1 – 30}, default = 10
Time measured while waiting to the server's response before sending a request retry.
Server request retries
Number {1 – 7}, default = 3
Number of request retries in case of M!DGE3 did not receive a valid reply.
Additional expert parameters shall be set in the ADVANCED menu.
The level of access is realised by Management-Privilege-Level (RFC 5607, index 136, type integer).
The level for each account shall be set during the server configuration. The user access level will be
granted according to the integer ranges for individual role levels. When the server does not allow setting
of Management-Privilege-Level the static account level option (for all users) has to be used.
7.5.4. Tamper reset
Tamper is a detection service, which is triggered, when the M!DGE3 chassis is physically opened.
There are 2 contacts (securing top and bottom casing) and the event is triggered even if the unit is
without power. When the chassis is opened an alarm is triggered and shown in Status report. Triggered
Tamper stops the RTC which means, that after every unit reboot, the unit timer is set back on the time,
when the Tamper was triggered. If an automatic time synchronization is not set, the system needs to
be set manually.
125
© RACOM s.r.o. – M!DGE3 Cellular Router
Settings
Содержание M!DGE3
Страница 2: ......
Страница 11: ...2 1 Dimensions Fig 2 1 M DGE3 dimensions 11 RACOM s r o M DGE3 Cellular Router Product...
Страница 116: ...M DGE3 Cellular Router RACOM s r o 116 Settings...
Страница 134: ...Tab 7 3 Configuration versions FW version CNF version 2 0 13 0 1 M DGE3 Cellular Router RACOM s r o 134 Settings...