ACK timeout [ms]
Number {0 – 16383}, default = 1000
Serial interface acknowledge timeout.
Repeats
Number {0 – 31}, default = 3
Number of repeats. Repetition is triggered when NAK frame is received or if ACK frame was not
received within ACK timeout.
Security bit
List box {On; Off}, default = "Off"
Needed for compatibility with legacy MORSE network implementations. This parameter does not
change protocol behaviour.
CRC
List box {On; Off}, default = "Off"
Error detection algorithm:
• On - CRC algorithm is used
• Off - XOR algorithm is used
7.1.2.3.9. Modbus RTU
Modbus RTU is a serial polling-type communication protocol used by Master-Slave application.
When M!DGE3 radio network run in Router mode, more Modbus Masters can be used within one Radio
network and one Slave can be polled by more Masters.
M!DGE3 Cellular Router – © RACOM s.r.o.
56