Source IP / mask, Destination IP / mask
Monitoring output can also be limited to a specific address range - Source and Destination IP address
and mask can be used to define the required range.
8.5.1.3. General
The settings of output parameters for file output –
Max. file size
and
Time period
, the first parameter
matched closes the monitoring file. File is saved in compressed way, so the uncompressed and approx-
imate compressed size is displayed in the list box.
Max. file size
List box {7 kB (~1 kB); 70 kB (~10 kB); 358 kB (~50 kB); 700 kB (~100 kB); 3 MB (~500 kB); 7 MB
(~1 MB); max (~2 MB)}, default = "700 kB (~100 kB)"
Time period
List box {1 min; 2 min; 5 min; 10 min; 20 min; 30 min; 1 hour; 3 hours; 24 hours; Off}, default = "5
min"
Show time difference
List box {On; Off}, default = "Off"
When On, the time difference between subsequent packets is displayed in the monitoring output.
8.5.2. File output
Record / Stop recording
button starts / stops recording to the file. The recording will be stopped im-
mediately regardless of the size and time of recording. When the Record button is pressed for the
second time the previously recorded data will be cleared.
Refresh
button – refreshes the information about time remaining and size of the recorded data (in un-
compressed way).
Download
button – downloads file to a connected computer. The default name contains of the Unit
name, date and time of the begin and day and time of the end of the monitoring. Before downloading
you have to stop recording.
M!DGE3 Cellular Router – © RACOM s.r.o.
164