184
Copyright@2004~2014 Qsan Technology, Inc. All Rights Reserved.
Qsan Document – User Manual
INFO
PD global spare
Assign JBOD <name> PD <slot> to Global Spare Disks.
ERROR
Config read fail
Config read error occurred at LBA <address>-<address> of
JBOD <name> PD <slot>.
ERROR
Config write fail
Config write error occurred at LBA <address>-<address> of
JBOD <name> PD <slot>.
DEBUG
PD read error
Read error occurred at LBA <address>-<address> of JBOD
<name> PD <slot>.
WARNING
PD write error
Write error occurred at LBA <address>-<address> of JBOD
<name> PD <slot>.
INFO
PD scrub started
JBOD <name> PD <slot> starts disk scrubbing process.
INFO
PD
scrub
completed
JBOD <name> PD <slot> completed disk scrubbing process.
WARNING
PS fail
Power Supply of <string> in JBOD <name> is FAIL
INFO
PS normal
Power Supply of <string> in JBOD <name> is NORMAL
WARNING
FAN fail
Cooling fan of <string> in JBOD <name> is FAIL
INFO
FAN normal
Cooling fan of <string> in JBOD <name> is NORMAL
WARNING
Volt warn OV
Voltage of <string> read as <string> in JBOD <name> is
WARN OVER
WARNING
Volt warn UV
Voltage of <string> read as <string> in JBOD <name> is
WARN UNDER
WARNING
Volt crit OV
Voltage of <string> read as <string> in JBOD <name> is CRIT
OVER
WARNING
Volt crit UV
Voltage of <item> read as <string> in JBOD <name> is CRIT
UNDER
INFO
Volt recovery
Voltage of <string> in JBOD <string> is NORMAL
WARNING
Therm warn OT
Temperature of <string> read as <string> in JBOD <name> is
OT WARNING
WARNING
Therm warn UT
Temperature of <string> read as <string> in JBOD <name> is
UT WARNING
WARNING
Therm fail OT
Temperature of <string> read as <string> in JBOD <name> is
OT FAILURE
WARNING
Therm fail UT
Temperature of <string> read as <string> in JBOD <name> is
UT FAILURE
INFO
Therm recovery
Temperature of <string> in JBOD <name> is NORMAL
INFO
JBOD HDD path NG Path redundancy to JBOD <name> PD <number> is lost
INFO
PD RPS started L2F
Assign JBOD <name> PD <slot> to replace PD <slot>.
INFO
PD RPS started F2L
Assign PD <slot> to replace JBOD <name> PD <slot>.
INFO
PD RPS started F2F
Assign JBOD <name> PD <slot> to replace JBOD <name> PD
<slot>.
INFO
PD RPS finished
L2F
PD <slot> is replaced by JBOD <name> PD <slot>.
INFO
PD RPS finished
F2L
JBOD <name> PD <slot> is replaced by PD <slot>.
INFO
PD RPS finished
F2F
JBOD <name> PD <slot> is replaced by JBOD <name> PD
<slot>.
ERROR
PD RPS failed L2F
Failed to replace PD <slot> with JBOD %4d PD <slot>.
ERROR
PD RPS failed F2L
Failed to replace JBOD <name> PD <slot> with PD <slot>.
ERROR
PD RPS failed F2F
Failed to replace JBOD <name> PD <slot> with JBOD
<name> PD <slot>.
ERROR
PD VD read write
fault
Read error at LBA <address>-<address> of JBOD <name> PD
<slot> and rewrite failed at LBA <address>-<address> of VD
<name>.