If
Auto Shutdown
is checked, the system will shutdown automatically when the voltage or
temperature is out of the normal range. For better data protection, it is recommended to check
Auto Shutdown
.
For better protection and avoiding single short period of high temperature that could trigger an
automatic shutdown, the system uses to gauge if a shutdown is needed. This is done using several
sensors placed on key systems that the system checks every 30 seconds for present temperatures.
The core processor temperature limit is 80
℃
.
The interface temperature limit is 65
℃
.
The SAS Controller and SAS Expandor temperature limits are 65
℃
.
When one of these sensors reports a temperature above the threshold for three contifuous
minutes, the system shuts down automatically.