178
Copyright@2004~2014 Qsan Technology, Inc. All Rights Reserved.
Qsan Document – User Manual
Troubleshooting
6
System Buzzer
The system buzzer features are listed below:
The system buzzer alarms 1 second when system boots up successfully.
The system buzzer alarms continuously when there is error occurred. The alarm will be
stopped after error resolved or be muted.
The alarm will be muted automatically when the error is resolved. E.g., when RAID 5 is
degraded and alarm rings immediately, user changes / adds one physical disk for rebuilding.
When the rebuilding is done, the alarm will be muted automatically.
Event Notifications
Physical Disk Events
Level
Type
Description
INFO
PD inserted
Disk <slot> is inserted into system
WARNING
PD removed
Disk <slot> is removed from system
ERROR
HDD read error
Disk <slot> read block error
ERROR
HDD write error
Disk <slot> write block error
ERROR
HDD error
Disk <slot> is disabled
ERROR
HDD IO timeout
Disk <slot> gets no response
INFO
PD upgrade started PD [<string>] starts upgrading firmware process.
INFO
PD upgrade
finished
PD [<string>] finished upgrading firmware process.
WARNING
PD upgrade failed
PD [<string>] upgrade firmware failed.
INFO
PD RPS started L2L
Assign PD <slot> to replace PD <slot>.
INFO
PD RPS finished
L2L
PD <slot> is replaced by PD <slot>.
ERROR
PD RPS failed L2L
Failed to replace PD <slot> with PD <slot>.
Hardware Events
Level
Type
Description
WARNING
ECC single
Single-bit ECC error is detected at <address>
ERROR
ECC multiple
Multi-bit ECC error is detected at <address>
INFO
ECC dimm
ECC memory is installed
INFO
ECC none
Non-ECC memory is installed