RS-1600-FC-FFX2 
Installation and User Guide

Part No. 37592-03A

Issue 3.0

March 10, 2003

Содержание RS-1600-FC-FFX2

Страница 1: ...RS 1600 FC FFX2 Installation and User Guide Part No 37592 03A Issue 3 0 March 10 2003...

Страница 2: ...all information in this document is accurate the Authors accept no liability for any errors that may arise No part of this document may be transmitted or copied in any form or by any means for any pu...

Страница 3: ...1 2 2 Tower Option 3 1 3 The Plug in Modules 4 1 3 1 Power Supply Cooling Module 4 1 3 2 Operators Panel 6 1 3 3 Loop Resiliency Circuit Input Output Module FC FFX2 7 1 3 4 Drive Carrier Module 10 1...

Страница 4: ...Tools 27 2 6 FC FFX2 FC AL Interface 28 2 6 1 Connecting Multiple Enclosures 28 2 7 LRC I O Module Installation 29 2 7 1 Parts Check List 29 2 7 2 Procedure 29 2 8 Drive Enclosure Device Addressing 3...

Страница 5: ...7 4 5 Drive Carrier Module Faults 47 4 5 1 Dummy Carrier Modules 47 4 5 2 Auto Start Failure 48 4 6 Dealing with Hardware Faults 48 4 7 Continuous Operation During Replacement 48 4 8 Replacing a Modul...

Страница 6: ...iv RS 1600 FC FFX2 User Guide Intentionally Blank...

Страница 7: ...signed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and...

Страница 8: ...without all units in place Permanently unplug the unit if you think that it has become damaged in any way and before you move it Drive Carrier Module Caution Label Do not operate with modules missing...

Страница 9: ...C or 200 240 VAC The plug on the power supply cord is used as the main disconnect device Ensure that the socket outlets are located near the equipment and are easily accessible The equipment is intend...

Страница 10: ...s used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired A faulty Power Supply Cooling module must be replaced with a fully operational module with...

Страница 11: ...als on the power supply must only be located in a RESTRICTED ACCESS LOCATION where both of the following apply Ref UL60950 access can only be gained by SERVICE PERSONNEL or by USERS who have been inst...

Страница 12: ...uld take into consideration the maximum operating ambient temperature for the unit which is 40 C when dual cooling modules are fitted The rack should have a safe electrical distribution system it must...

Страница 13: ...o invalidate the warranty If you remove any drive module you may lose data If you remove a drive module replace it immediately If it is faulty replace it with a drive module of the same type and capac...

Страница 14: ...the PSU Danger of electric shock inside Return the PSU to your supplier for repair Battery Safety page x section rewritten Warning inserted as follows Warning The battery is not user replaceable there...

Страница 15: ...mix PSU Cooling modules of different types Section 2 4 2 note added Important PSU2 RH rear bay must be fitted upside down as shown in Figure 2 1 Sections 2 5 2 5 1 and 2 6 para titles FC FFX2 FCAL cha...

Страница 16: ...ed to 4 8 6 and new section 4 8 5 inserted Battery Replacement Section 4 9 Battery added to spare parts list Glossary Definitions of Module and ESI Ops panel revised to reflect the fact that the ESI O...

Страница 17: ...v 3 0 February 24 2003 Chapter 1 Table 1 1 Switch 3 RAID Host FC ports will not be linked together internally changed to RAID Host FC ports will be linked together internally Version Date Description...

Страница 18: ...RS 1600 FC FFX2 User Guide xvi Intentionally Blank...

Страница 19: ...Introduction 1 Chapter 1 Introduction 1 1 The RS 1600 FC FFX2 System Figure 1 1 The RS 1600 FC FFX2 FC AL System...

Страница 20: ...sembly also includes an integral Ops Panel mounted at the rear The chassis assembly contains 16 drive bays at the front each of which accommodates a plug in drive carrier module The 16 drive bays are...

Страница 21: ...Introduction 3 1 2 2 Tower Option An optional tower kit is available which can be fitted to the rack chassis described here Figure 1 3 Enclosure Chassis Rear Figure 1 4 RS 1600 FC FFX2 Tower Option...

Страница 22: ...SU Cooling module 48V DC 450W PSU Cooling module Warning Do not mix PSU Cooling modules of different PSU Cooling Module Two Power Supply Cooling modules Figure 1 5 are supplied mounted in the rear of...

Страница 23: ...nt within the module 1 3 1 2 Multiple Power Supply Cooling Modules The RS 1600 FC FFX2 system must always be operated with two Power Supply Cooling modules fitted The two Power Supply Cooling modules...

Страница 24: ...Enclosure 1 3 2 1 Ops Panel Indicators and Switches The Ops Panel includes Light Emitting Diodes LEDs which show the status for all modules an Audible Alarm which indicates when a fault state is prese...

Страница 25: ...losure management and interface to devices on the Backplane PSU LRC and Ops Panel to monitor internal functions These processors operate in a master slave configuration to allow failover Table 1 1 Ops...

Страница 26: ...indicator Cache Active Green RAID Activity Green RAID Fault Amber ESI LRC module fault LED Amber The enclosure may be configured with either 1 or 2 RAID modules If only 1 module is fitted a matching...

Страница 27: ...tion 9 Warning Do not attempt to lift the enclosure by means of the extended LRC module Figure 1 9 FC FFX2 LRC I O Module Figure 1 10 RS 1600 FC FFX2 Enclosure with FC AL LRC I O Modules and AC PSUs I...

Страница 28: ...ier module comprises a hard disk mounted in a carrier Each drive bay will house a single 1 0 inch high 3 5 inch disk drive in its carrier Each disk drive is enclosed in a die cast aluminum carrier whi...

Страница 29: ...will be ON and will flicker as the drive operates 1 3 4 2 Anti tamper Locks Anti tamper locks are fitted in the drive carrier handles Figure 1 13 and are accessed through the small cutout in the latch...

Страница 30: ...ules LEDs show constant green for good or positive indication Constant Amber LEDs indicate there is a fault present within that module The Ops Panel also incorporates an Audible Alarm to indicate when...

Страница 31: ...tage Range Selection Automatic Frequency 50 60 Hz Inrush Current 50A 260VAC Power Factor 0 98 Harmonics Meets EN61000 3 2 DC Input Voltage Range 40V to 60V DC Rated DC Line Inrush Current 50A peak Saf...

Страница 32: ...0 000ft Altitude Non Operational 305 to 12 192m 1000 to 40 000ft Shock Operational Vertical axis 5g peak 1 2 sine 10ms Shock Non Operational 30g 10ms 1 2 sine Vibration Operational 0 21grms 5 500 Hz R...

Страница 33: ...op of 16 drives 1 external port SFP GBIC connectors 2 host SFP GBIC ports hubbed together Mounting Rear single bays 3 and or 4 see Figure 1 3 Connectors 2 x SFP module LC optical max cable length 500m...

Страница 34: ...ics as Enclosure temperature Fan speed Drive condition Operator panel status For more information on the implementation of this function please request a copy of the SES specification from your suppli...

Страница 35: ...L configurations and installation Table 2 1 RS 1600 FC FFX2 Configuration Module Location Drive Bays ALL drive bays must be fitted with either a drive carrier module or a dummy carrier no bays should...

Страница 36: ...Important Drive carrier module must always be fitted in locations 1 1 drive 0 and 4 4 drive 15 This is the minimum configuration required for the system to operate and provide SES Management Services...

Страница 37: ...enclosure The rack should present a maximum back pressure of 5 pascals 0 5mm water gauge 2 3 2 Rack Mounting Rail Kit A set of mounting rails is available for use in 19 inch rack cabinets These rails...

Страница 38: ...ach bay 4 Screw the 4 front rack mount screws through the flanges and tighten 5 Fit and tighten the rear hold down screws ensuring the enclosure is in tight contact to both the side and top of the cha...

Страница 39: ...e module if any pins appear to be bent 2 With the PSU handle in the open position Figure 2 3 slide the module into the enclosure Figure 2 4 3 Cam the module home by manually closing the PSU handle Fig...

Страница 40: ...RS 1600 FC FFX2 User Guide 22 Figure 2 4 Installing an AC Power Supply Cooling Module 1 Figure 2 5 Installing an AC Power Supply Cooling Module 2...

Страница 41: ...e gained by SERVICE PERSONNEL or by USERS who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shall be taken and access is through th...

Страница 42: ...nnecting devices shall not be in the earthed circuit conductor between the dc source and the point of connection of the earthing electrode conductor Protective Earth Conductor Size The protective eart...

Страница 43: ...the module home by manually closing the PSU handle see Figure 2 7 A click should be heard as the handle latches engage see Figure 2 8 Figure 2 6 I 48V PSU Module Handle in Open Position Figure 2 7 in...

Страница 44: ...inal block cover 8 Turn the supply power back on 9 Switch on power at the PSU switch 2 4 3 4 Wiring Instructions for 48V DC PSU Warning The 48V and 48V terminals are not connected to chassis earth 1 F...

Страница 45: ...re 2 1 these contain Port Bypass Circuits PBC that provide loop resiliency in the event of unplugged or failing drives Note Figure 2 11 shows the logical routing of the FFX2 FC AL interface through th...

Страница 46: ...no external terminators required with Fibre Channel architecture and any drive may be hot plugged during operation 2 6 1 Connecting Multiple Enclosures Multiple enclosures are connected together by u...

Страница 47: ...rface connector do not install if any pins are bent 1 The modules should be installed in rear bays 3 and 4 of the Enclosure Figure 2 1 Note LH and RH modules are fitted in opposite orientations as sho...

Страница 48: ...ss ranges see Table 2 2 The SEL_ID base address is set by means of the thumb wheel switch on the Ops Panel at the rear of the enclosure It is recommended that the RS 1600 FC FFX2 is given ID1 The Mode...

Страница 49: ...16 Drive switch range setting SWITCH Device slot 1 2 7 RAID 0 0 N A continued up to N A RAID 1 1 N A N A SES Tgt 1 N A N A N A SES Tgt 2 N A N A N A Drive 1 1 4 20 100 Drive 1 2 5 21 101 Drive 1 3 6...

Страница 50: ...ith either a drive carrier or front dummy fascia no bays should be left completely empty 2 9 1 2 Drive Configuration Important After you have installed the drive carrier modules in your RS 1600 FC FFX...

Страница 51: ...e carrier gently all the way into the enclosure until it is stopped by the camming lever on the right of the carrier Figure 2 16 Figure 2 15 I FC FFX2 Drive Carrier Module Figure 2 16 Installing an FC...

Страница 52: ...verse of this procedure press on the latch to release the handle 2 10 3 Dummy Carrier Modules Any unused drive bays must be fitted with a dummy carrier module 2 10 4 Engaging the Anti tamper Locks The...

Страница 53: ...is no longer visible in the aperture beside the key Note A drive carrier cannot be installed if its anti tamper lock is activated outside the Enclosure 2 11 Power Cord Connection 2 11 1 Parts Check Li...

Страница 54: ...distribution and the enclosure If a direct connection is made with the RS 1600 FC FFX2 power cord ensure that it is connected to the enclosure Warning Some electrical circuits could be damaged if exte...

Страница 55: ...below to power up the enclosure 1 Apply AC Mains power to the enclosure Turn the Power Supply Cooling modules to ON 2 On the Ops Panel the Audible Alarm beeps once all LEDs flash for 7 seconds then t...

Страница 56: ...ated constant GREEN If a problem is detected the color of the relevant LED will change to AMBER 3 3 Ops Panel LEDs The Ops Panel LEDs fault and status conditions are defined in Table 3 2 and shown in...

Страница 57: ...U LEDs or Fan LEDs Any PSU fault or Fan fault On On Flash Over or Under temperature On Off On ESI LED on LRC ESI processor A Failed On Off On ESI LED on LRC ESI processor B Failed On Off On None Unkno...

Страница 58: ...is only one Power Supply Cooling Module present the drive motors will spin up in a delayed sequence 3 4 1 Disk Drives LEDs Each drive carrier incorporates two indicators an upper GREEN and lower AMBE...

Страница 59: ...lt is indicated on the Ops Panel please refer firstly to Table 4 2 and then to the section referenced within that table 4 1 1 Initial Start up Problems 4 1 1 1 Faulty Cords First check that you have w...

Страница 60: ...k the maximum cable length has not been exceeded 4 2 LEDs Green LEDs are always used for good or positive indication flashing Green Amber if non critical conditions exist Amber LEDs indicate there is...

Страница 61: ...en the Audible Alarm sounds it may be muted by pressing the Alarm Mute push button Automatic muting will take place after two minutes if the mute switch is not manually operated The Alarm Mute push bu...

Страница 62: ...ctions good On On Off PSU LEDs or Fan LEDs Any PSU fault or Fan fault On On Flash Over or Under temperature On Off On ESI LED on LRC ESI processor A Failed On Off On ESI LED on LRC ESI processor B Fai...

Страница 63: ...ons on the drives carriers If none are evident then there may either be an ESI processor problem or a Backplane problem 3 Change the Ops Panel module see 4 8 2 Symptom Cause Action 1 Ops Panel FAULTLE...

Страница 64: ...ol process is for the fans to automatically increase in speed when a thermal threshold is reached This may be caused by higher ambient temperatures in the local environment and may be perfectly normal...

Страница 65: ...ernal temperature measured in the airflow through the enclosure exceeds a pre set threshold a thermal alarm will sound 1 Check local ambient environment temperature is below the upper 40 C specificati...

Страница 66: ...module blanks missing for more than a few minutes the Enclosure can overheat causing power failure and data loss Such use will invalidate the warranty Replace a faulty drive with a drive of the same t...

Страница 67: ...ts installed you can continue working while replacing the faulty module 1 Make sure you identify the faulty Power Supply Cooling module correctly from the two modules installed 2 Switch off and discon...

Страница 68: ...RS 1600 FC FFX2 User Guide 50 Figure 4 2 Removing Inserting an AC Power Supply Cooling Module 1 Figure 4 3 Removing an AC Power Supply Cooling Module 2...

Страница 69: ...Removal procedures 1 Switch off power at the PSU switch 2 Remove all supply power by turning off the supply at the disconnect device located near to the equipment 3 Remove the terminal block cover 4 D...

Страница 70: ...RS 1600 FC FFX2 User Guide 52 Figure 4 5 Removing Inserting a 48V Power Supply Cooling Module 1 Figure 4 6 Removing Inserting a 48V Power Supply Cooling Module 2...

Страница 71: ...he Power Supply Cooling module Caution Handle the module carefully and avoid damaging the connector pins Do not install the module if any pins appear to be bent 2 With the PSU handle Figure 4 6 in the...

Страница 72: ...nals are not connected to chassis earth 1 For installations with 48V earthed a shorting link must be added see Figure 4 8 2 For installations with a separate earth connect the earth cable to the earth...

Страница 73: ...st not be run without all modules in place Note As there should always be two LRC I O modules installed you can continue working while replacing the faulty module 1 Ensure that you correctly identify...

Страница 74: ...the latch in the open position slide the LRC module into the enclosure until the latch engages automatically 2 Cam the module home by manually closing the latches see Figure 4 12 3 A click should be h...

Страница 75: ...ions Warning Risk of explosion if battery pack is replaced by an incorrect type The battery pack must only be replaced with a battery pack of the following type which contains current limiting and tem...

Страница 76: ...e three screws in the standoffs 4 Reconnect the battery by pushing the connector firmly into the pcb socket Note the polarization of the battery connector 5 Dispose of the battery in accordance with N...

Страница 77: ...pproximately1 inch 25mm and wait 30 seconds 3 Withdraw the module from the drive bay and fit a replacement module in accordance with the instructions in Section 2 10 Drive Carrier Installation 4 9 Spa...

Страница 78: ...RS 1600 FC FFX2 User Guide 60 Intentionally Blank...

Страница 79: ...wire used for the transmission of data signals between computer equipment Note Cable is UK preferred terminology for either a power cord or a data cable Character A representation coded in binary dig...

Страница 80: ...cooling modules and two LRC I O modules Operating system The software running the host computer For example on PCs it is often Windows 95 98 Windows NT or OS 2 and on Hewlett Packard machines it coul...

Страница 81: ...19 46 48 Enclosure Services Processor 41 Enclosure System Interface Operators Panel 6 ESD 18 49 ESI processor 45 f fan failure 45 FC_AL signal 42 h HSSDC 2 connectors 28 hub function 27 i I O Module 2...

Страница 82: ...User Guide 64 RAID controller 2 7 29 55 RS 1600 FC2 28 s SEL_ID base address 30 Select ID 42 SES xiii 31 32 SES Communications xiii 31 32 SFP connectors 28 SYSTEM LED 45 48 t tower 3 v Visible and Au...