Getting Started
17
Chapter 2
Getting Started
2.1 Introduction
In this chapter, you are shown how to install your RS-1600-FC-FFX2 Enclosure and plug-in modules into
an industry standard 19 inch rack cabinet.
Caution
When connecting up the RS-1600-FC-FFX2 system, use only the power cords supplied or cords which
match the specification quoted in section
1.5.6, ”Power Cord”, on page 13
.
2.2 Planning Your Installation
Before you begin installation you should become familiar with the configuration requirements of your RS-
1600-FC-FFX2 system, detailed in
Table 2–1
. The correct positions of each of the optional plug-in
modules are shown in
Figure 2–1
. Please refer to section for
2.5
details of FC-AL configurations and
installation.
Table 2–1
RS-1600-FC-FFX2 Configuration
Module Location
Drive Bays
ALL drive bays must be fitted with either a drive carrier module or a dummy
carrier, no bays should be left completely empty.
Power Supply/Cooling
Modules
Two Power Supply/Cooling modules must be fitted. Full power and cooling
redundancy is provided while a faulty module is replaced. Install the Power
Supply/Cooling modules in rear Bays 1 & 5.
Note: Rear bays are numbered from 1 to 5 commencing from the right
hand side)
LRC I/O Modules
Install in rear Bays 3 and 4.
Ops Panel
Installed in rear Bay 2 (integral part of chassis assembly)
Caution: Operation of the Enclosure with ANY modules missing will disrupt the airflow and the drives
will not receive sufficient cooling. It is ESSENTIAL that all apertures are filled before operating the unit.
Dummy Drive Carriers are available for this purpose.