Introduction
13
1.5.3 AC Power (450W PSU)
1.5.4 -48V DC Power (450W PSU)
1.5.5 PSU Safety and EMC Compliance
1.5.6 Power Cord
(minimum requirements)
Voltage Range
100-120 / 200-240 VAC Rated
Voltage Range Selection
Automatic
Frequency
50/60 Hz
Inrush Current
50A @ 260VAC
Power Factor
>0.98
Harmonics
Meets EN61000-3-2
DC Input Voltage Range
-40V to -60V DC Rated
DC Line Inrush Current
50A peak
Safety Compliance
UL 60950
IEC 60950
EN 60950
EMC Compliance
CFR47 ParT 15BClass A
EN55022
EN55024
Cord Type
SV 0r SVT, 18 AWG minimum, 3 conductor
Plug
250V, 10A
Socket
IEC 320 C-14, 250V, 15A