Operation
39
Please refer to
Chapter 4
, ”Troubleshooting and Problem Solving”, on page 41
for details of any fault
indication.
Table 3–2
Ops Panel LED States
Ops Panel LEDs
Other Associated
LEDs or Alarm
State Description
Power
(Green)
PSU/
Cooling/
Temp
(Amber)
System
(Amber)
Address
Mode
Error
(Amber)
FC-FFX2
Loop
Speed
Hub
Mode
Selected
On
Off
Off
Off
Off
Off
5V Aux present, overall power failed
On
On
On
On
On
On
single beep, then
double beep
Ops Panel power On (5s) test state
On
Off
Off
Off
Power On, all functions good
On
On
Off
PSU LEDs or Fan
LEDs
Any PSU fault or Fan fault
On
On
Flash
Over or Under temperature
On
Off
On
ESI LED on LRC
ESI processor A Failed
On
Off
On
ESI LED on LRC
ESI processor B Failed
On
Off
On
None
• Unknown (invalid or mixed)
LRC module type installed, or
• I2C Bus Failure (inter ESI
processor), or
• Backplane autostart watchdog
failed.
On
Flashing Flashing
PSU Removed
PSU removed and System power
redundancy check option set. No
indication if option not set.
On
Off
Flashing
No SES Drives fitted
On
Flashing
On
Intermittent
audible alarm
Ops to ESI Communications failed
On
Flashing
Invalid address mode setting
(change thumb wheel to valid
ranges)
On
On
2Gb FC-FFX2 Drive loop speed
selected
On
On
RAID ONLY
Host side Hub mode enabled
Содержание RS-1600-FC-FFX2
Страница 1: ...RS 1600 FC FFX2 Installation and User Guide Part No 37592 03A Issue 3 0 March 10 2003...
Страница 6: ...iv RS 1600 FC FFX2 User Guide Intentionally Blank...
Страница 18: ...RS 1600 FC FFX2 User Guide xvi Intentionally Blank...
Страница 78: ...RS 1600 FC FFX2 User Guide 60 Intentionally Blank...