Introduction
7
Caution
All mandatory settings must be observed in order for the RS-1600-FC-FFX2 system to function correctly.
1.3.3 Loop Resiliency Circuit Input/Output Module (FC-FFX2)
The RS-1600-FC-FFX2 storage subsystem includes an enclosure with rear facing bays which house two
Loop Resiliency Circuit (LRC) I/O modules with integrated Mylex San Array Pro
©
FFX2 RAID controller.
(see
Figure 1–3
)
The FC-AL Backplane incorporates two independent loops formed by Port Bypass Circuits within the LRC
I/O modules.
The plug-in LRC modules have been designed for integration into a RS-1600-FC-FFX2 storage
subsystem, utilizing FCAL interfacing with the host computer system.
Processors housed on the LRC modules provide enclosure management and interface to devices on the
Backplane, PSU, LRC and Ops Panel, to monitor internal functions. These processors operate in a
master slave configuration to allow failover.
Table 1–1
Ops Panel Switch Functions (Default settings for RS-1600-FC-FFX2 LRC usage at 2Gb/s)
Switch
Number
Function
Recommended
Setting
Definition
1
Loop Select,
Single (1x16) or
Dual (2x8)
On
LRC operates on single loop of 16 drives
Mandatory
2
Loop Terminate Mode
On
If No Signal is present on External FC port
the loop will be “healed” internally
3
Hub Mode Select
On
RAID Host FC ports will be linked together
internally
4
Not Used
5 & 6
RAID Host Hub Speed
Select switches
Sw5
Sw6
On
Off
Force 2Gb/s
Off
Off
Force 1Gb/s
7 & 8
Drive Loop Speed
Select
Sw7
Sw8
On
Off
Force 2Gb/s
Off
Off
Force 1Gb/s
9 & 10
Drive Addressing
Mode Selection
Sw9
Sw10
On
On
Mode 0
11
SOFT SELECT
On
Select Functions using the hardware
switches
12
Not Used