45
d
x
d
c
76
34a
34
35.5
78
78
76
1.875 m
1.500 m
2.375 m
1.781 m
2.875 m
1.719 m
3.750 m
1.625 m
4.375 m
1.563 m
B2 Planning the Units
Renforced platform extension with 3
Platform Beams
For a reinforced design with 3 Platform
Beams, the permisible cantilever d is in-
creased. See Table 5.
The additional Platform Beams (34a) are
mounted centrally beween the available
Platform Beams (34).
All three Platform Beams are bolted to
two timbers (76) as trimmer using Bolts
M8x100 (78).
(Fig. B2.08)
Minimum spacing x > d x 0.5
Components
34
Platform Beam LPS
34a
Platform Beam LPS 235 or 285
35.5
Platform Cover LPS 37.5 x 107.5
76
Timber 80/80 mm, length 0.80 m
78
Flat Round Screw DIN 603
M8x100 MU
Fig. B2.08
Permissible cantilever with 3 Platform Beams
Bracket spacing
c
Permissible cantilever
d
Table B2.03
LPS Screen Lightweight Climbing Enclosure
Instructions for Assembly and Use – Standard Configuration