B1 Planning the Supporting Structure
Dependence on Storey Heights
Version 1
Climbing enclosure with straight, contin-
uous screen elements.
For mounting Screen Elements DX LPS
(21), the Climbing Rails-2 LPS (2) can be
extended upwards to realise larger pro-
tection heights.
The extension is carried out using Steel
Waler Universal SRU (3) and Rail Con-
nector SRU/LPS (6).
The number and position of the screen
elements depend on the respective floor
height, as well as the required upper
projection.
Screen elements with a height of 1.23 m
are mounted on the climbing rails in a
system dimension of 1.25 m. The re-
quired space of 2 cm for the grid adapt-
ers has been taken into account in the
system dimension.
The protection area is reduced for all
combinations by 2 cm through the top
and bottom grid adapters.
For Version 1, Climbing Rail LPS 998 is
provided as standard. As a result, a pro-
tection height of 8.73 m is possible.
For other possible combinations, see
Table B1.01 and illustrations.
Larger protection heights are achieved
by means of the extension with Steel
Waler SRU. Extension dimensions are
limited by the load-bearing capacity of
the Rail Connector SRU/LPS.
Other Version 1 combinations are not
covered by the standard configuration
and require static verification.
Components
2
Climbing Rail-2 LPS 748 or 998
3
Steel Waler Universal SRU
6
Rail Connector SRU/LPS
21
Screen Element DX LPS
4
,74
m
5
,2
4 m
2
,2
4 m
2
,2
4 m
2
,5
0 m
3
,0
0 m
2
,5
0 m
3
,0
0 m
7,
4
8
m
8
,7
3
m
Fig. B1.04
Fig. B1.05
h
B
= 2,50 m
h
B
= 3,00 m
LPS Screen Lightweight Climbing Enclosure