FL20-CA Series
42
Connectors
Precautions on the connector parts as below:
Make sure there are no foreign matters such as dust and metal chips in the
connector before connecting.
When the connectors are connected to the motor, make sure to connect from
the side of servo motor main-circuit cables firstly, and the grounding cable
must be earthed reliably. If connecting from the side of encoder cables firstly,
encoder fault may occur because of the potential difference between PE.
Make sure the correct pin arrangement.
Do not exert force to connector, which is made from resin.
When handling a servo motor with its cable connected, do not exert force to
the connector. The connector may be damaged because of the stress.
3.2.4
Servo motor dimension
Dimension between shaft front face and flange face
Flange lug height of motor face
A
A
A-A
Dimension between shaft front
face and shaft shoulder
Tolerance grade not noted
refer to GB/T-1804- 2000-M
4- core supply plug
15-core incremental
encoder plug
7-core absolute
encoder plug
Fig 3.2.1 Motor installation dimension
Model
L(mm)
Weight
(
Kg
)
L
(
mm
)
With brake
Remarks
FMSA-201F/S32***
130.5
1.2
162.5
The screw hole size:
M4 X 12
FMSA-401F/S32***
163
1.6
195
Содержание FL20-CA Series
Страница 33: ...FL20 CA Series 33 H 1 1 1 1 I 22 22 25 25 J M5 M5 M5 M6 K 20 22 5 25 25 L2 29 5 29 5 39 5 37 5 ...
Страница 38: ...FL20 CA Series 38 M4 structure dimension unit mm Fig 3 1 7 Servo drive structure size 5 ...
Страница 39: ...FL20 CA Series 39 M5 structure dimension unit mm Fig 3 1 8 Servo drive structure size 6 ...