263
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
1
~
32000
0.1rpm
30000
Immediate
Function code
Mapping
Data type
Accessibility
So-22
N
UINT16
RW
The entry-into-effect time is 1000ms.
Sub-index 18h
Motor parameter storing location
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
1
N/A
1
Immediate
Function code
Mapping
Data type
Accessibility
So-23
N
UINT16
RW
0: When servo drive finishes auto-tuning motor parameter, motor parameters are stored
in servo drive.
1: When servo drive finishes studying motor parameter, motor parameters are stored in
encoder. (Only for encoder with EEPROM)
Sub-index 19h
Analog monitor voltage compensation 1
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
-10000~10000
mv
0
Immediate
Function code
Mapping
Data type
Accessibility
So-24
N
INT16
RW
The entry-into-effect time is 1000ms.
Sub-index 1Ah
Motor parameter identification setting
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
4
N/A
0
Immediate
Function code
Mapping
Data type
Accessibility
So-25
N
UINT16
RW
Please refer to chapter 7.
Sub-index 1Bh
Fan control
PP PV PT CSP CSV CST HM
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
2
N/A
2
Immediate
Function code
Mapping
Data type
Accessibility
So-26
N
UINT16
RW
Содержание FL20-CA Series