309
AL-12
Servo drive
overheat
Environment temperature is too
high
Improve ventilation
Dirty radiator.
Clean air outlet and radiator.
Foreign matters in fan
Clear out foreign matters
Fan damage
Replace fan
Improper installation of drive,
such as poor ventilation or
wrong installation direction.
Install as required
Too heavy load
Discharge energy is too large
AL-13
Power supply
phase loss of
main circuit
When main circuit is powered
on, one phase voltage of three
is too low.
Check phase loss of input
power supply.
Use single-phase power supply. Check parameter setting
AL-14
Energy
consumption
error
Wrong braking resistor
parameter
Modify parameter value
Continuous brake time is too
long
Check load, servo drive only
can
drive
non-potential
energy load.
AL-16
Duplicate setting
of input terminal
Duplicate definition of input
terminals
Reset to avoid duplicate
definition
AL-17
Encoder cable
disconnected
Encoder cable disconnected
Encoder cable disconnected
AL-18
Rotation inertia
recognition fault
Rotation inertia recognition
fault
Turn up Po013 manually
AL-19
Alarm of encoder
battery
Battery alarm of encoder
1. Check whether encoder
cable is connected normally.
If cable is disconnected,
connect again and reset alarm.
2. Check whether battery
capacity is 3.6V.
If it is lower than 3.2V,
change battery and reset
alarm when servo drive
control power is ON state.
3. Shielding AL-19:
So-38=1
,
So-43=1 reset
alarm.
4. Check whether the wiring
of battery is reliable if user
makes cable by himself.
Содержание FL20-CA Series
Страница 33: ...FL20 CA Series 33 H 1 1 1 1 I 22 22 25 25 J M5 M5 M5 M6 K 20 22 5 25 25 L2 29 5 29 5 39 5 37 5 ...
Страница 38: ...FL20 CA Series 38 M4 structure dimension unit mm Fig 3 1 7 Servo drive structure size 5 ...
Страница 39: ...FL20 CA Series 39 M5 structure dimension unit mm Fig 3 1 8 Servo drive structure size 6 ...