248
Sub-index 27h
Internal position given speed unit PP CSP
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
1
N/A
0
Immediate
Function code
Mapping
Data type
Accessibility
Po338
N
INT16
RW
0: Motor actual speed, no related to electronic gear ratio, unit is 0.1rpm
1:0.01KHz, frequency division processing is done by electronic gear ratio.
Sub-index 28h
Electronic gear selection PP CSP
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
2
N/A
1
Immediate
Function code
Mapping
Data type
Accessibility
Po339
N
INT16
RW
The entry-into-effect time is 100ms.
0: The first electronic gear ratio
1: The second electronic gear ratio
3: DI terminal selection
Sub-index 4Dh
Position feedback source PP CSP
Setting Range
Setting Unit
Mfr’s Value
Effect
0
~
2
N/A
0
Immediate
Function code
Mapping
Data type
Accessibility
Po376
N
INT16
RW
0: encoder 1: high-speed counter 1 3: high-speed counter 2
Sub-index 4Eh
External encoder proportion numerator PP CSP
Setting Range
Setting Unit
Mfr’s Value
Effect
1
~
65535
N/A
1
Immediate
Function code
Mapping
Data type
Accessibility
Po377
N
UINT16
RW
Sub-index 4Fh
External encoder proportion denominator PP CSP
Setting Range
Setting Unit
Mfr’s Value
Effect
1
~
65535
N/A
1
Immediate
Function code
Mapping
Data type
Accessibility