156
6084h
00h
Profile
deceleration time
RW
UINT16
ms
0
~
32000
100
7.4.2 Related functions
Index
Sub-index
Name
Description
606Dh
00h
Velocity
threshold
When the difference between 60FFh (converted
into motor speed/RPM) and actual motor speed
is within ±606Dh, and the time reaches 606Eh,
the servo drive considers that the speed
reference is reached, sets status word 6041h
bit10 = 1 and activates the speed reached DO
signal.
This flag bit is valid only when the S-ON signal
is valid in profile position mode and cyclic
synchronous velocity mode.
606Eh
00h
Velocity
window
7.4.3 Recommended configuration
RPDO
TPDO
Remarks
6040h: control word
6041h: status word
Mandatory
60FFh: target velocity
Mandatory
6064h: position actual value
Optional
606Ch:velocity actual value
Optional
6083h: profile acceleration
Optional
6084h: profile deceleration
Optional
6060h: modes of operation
6061h: Modes of operation display
Optional
7.5 Profile torque mode (PT)
In this mode of operation, the controller gives the target torque in 6071h to the servo drive.
Torque control is performed by the servo drive. The servo drive will supply actual position
value, actual velocity value and actual torque value.