INSTALLATION AND OPERATION MANUAL 

HS1H 

 

 

 

 
 

PIEZOCONCEPT 

15 Rue du Bocage 

69008 LYON 

France 

Summary of Contents for HS1H

Page 1: ...1 INSTALLATION AND OPERATION MANUAL HS1H PIEZOCONCEPT 15 Rue du Bocage 69008 LYON France ...

Page 2: ...om the PIEZOCONCEPT controller first set the command voltage to 0 0V then turn the AC power to the PIEZOCONCEPT controller off and finally wait one minute before disconnecting The HS1H has no user serviceable parts Only trained service personnel should perform service IMPORTANT All Technical Information recommendations and examples related to PIEZOCONCEPT Products made in this manual are based on ...

Page 3: ...1 3 HS1H 5 2 INSTALLATION 5 2 1 Installing a single axis HS1H unit 5 2 2 Installing a two axis HS1H unit 6 3 GROUND LOOPS 6 3 1 Prevention and identification of ground loops 7 4 OPERATING THE NANOPOSITIONING STAGE 7 4 1 Operating in closed loop mode 7 4 2 Care during operation 8 ...

Page 4: ...ientific instrument and therefore requires special handling in order to ensure proper operation Mishandling can cause permanent damage to the nanopositioning stage To ensure a long and useful life the following guidelines should be strictly followed Never insert anything into the EDM grooves The EDM grooves are the cuts that form the flexure hinges and separate the moving portion of the stage Do n...

Page 5: ...ing a single axis HS1H unit To install a single axis HS1H use the following steps On the surface that the HS1H is to be mounted on tap M3 holes on a 79X52 50mm rectangle Make sure the surface to be mounted to is clean flat and free of burs Using a lint free cloth gently wipe off the bottom of the HS1H to remove any particles or dust Use M3 Socket screws to secure the stage Use a maximum torque of ...

Page 6: ...n the four M2 5 flat head screws Do not hold on to the bottom or Y axis while loosening To install a two axis HS1H system use the following steps 1 Install the first or bottom HS1H Y axis using the procedures described above in Section 2 1 2 Using a lint free cloth gently wipe off the top of the installed HS1H and the bottom of the adapter plate to remove any particles or dust 3 Using four M2 5 sc...

Page 7: ...our mounting surface Mounting surfaces should never be used as the electrical ground current path for any instrumentation such as vacuum pumps computers etc Should you observe unexpected oscillations in your nanopositioning stage after you have switched on the power this likely indicates the continued presence of a ground loop or excessive sample mass see Section 2 SWITCH THE SYSTEM OFF IMMEDIATEL...

Page 8: ...NCEPT CONTROLLER OPERATION MANUAL 4 2 Care during operation The HS1H is a high precision scientific instrument and should be handled with care during operation Failure to do so may result in permanent damage During operation ensure that there are no physical constraints on the moving stage or anything fixtured to the moving stage Never apply a voltage greater than 150V or less than 5V to the PZT M...