Parker EME
Setting up Compax3
192-120103 N13 C3I20T11 / C3I32T11 December 2010
155
Zeitraster Signalquelle Master
Averaging and a following filter (interpolation) can help to avoid steps caused by
discrete signals.
If the external signal is analog, there is no need to enter a value here (Value = 0).
For discrete signals e.g. from a PLC, the scanning time (or cycle time) of the signal
source is entered.
T
t
This function is only available if the analog int/-10V is used!