Setting
up Compax3
C3I20T11 / C3I32T11
272
192-120103 N13 C3I20T11 / C3I32T11 December 2010
(1) Start and Stop of the measurement
(2) Status display
Current status of the measurement or of the controller (if no measurement is taking
place).
(3) Progress of the registration of the signals in the controller
The time of registration of the signals in the controller itself can, depending on the
bandwidth and the kind of measurement, take up to one minute.
(4) status of the activity of the different partitions of the measurement
a: Registration of the measurement in the controller
b: Upload of the measurement from the controller to the PC
c: Processing the measurement in the PC