Parker EME
Setting up Compax3
192-120103 N13 C3I20T11 / C3I32T11 December 2010
273
(5) Different settings and options
Functions available in a pull-down menu:
Open superimposed control loops
(see on page 256)
accept load force
This serves, when opening the velocity controller, to accept the load which the
controller has provided at the time of switching off => a z-axis does not drop down
abruptly.
Measurement synchronous to the test movement
If this option is selected, it is ensured during the measurement, that the sampling
does not take place in the turning point during a movement.
Unless frequencies are generated due to the deceleration/acceleration of the drive,
which influence the measurement.
Result memory
In the result memory, the results of the N last measurements are kept.
This is important for the display of the cumulated measurement and for the
cascade diagram. The larger the memory, the "older" the results still used. When
the contents is deleted, all old measurements are discarded and do no longer
influence the new results.
Windowing
Here you can select different windowing modes for the measurement of frequency
spectra. As default, no window is used.
Save measure to file
The currently displayed measurement result is stored and can be uploaded later
into the ServoSignalAnalyzer. This does, however, not apply to the cascade
diagram display.
Open measure from file
Here you can reload the measurements memorized before. You have the
possibility to load up to four measurements subsequently and display them
together in a graphic display.
Copy measurement to clipboard as graphic display.
The currently displayed measurement result is copied as pixel graphic (e.g. BMP)
to the clipboard.