Technical
Characteristics
C3I20T11 / C3I32T11
406
192-120103 N13 C3I20T11 / C3I32T11 December 2010
Mains connection Compax3HxxxV4 3*400VAC
Device type Compax3
H050V4
H090V4
H125V4
H155V4
Supply voltage
Three-phase 3*400VAC
350-528VAC / 50-60Hz
Input current
66Arms
95Arms
143Arms
164Arms
Output current
50Arms
90Arms
125Arms
155Arms
Maximum fuse rating per
device(=short circuit
rating)
Branch circuit protection
according to UL
80A
100A
160A
200A
JDDZ Class K5 or H
JDRX Class H
Mains connection Compax3HxxxV4 3*480VAC
Device type Compax3
H050V4
H090V4
H125V4
H155V4
Supply voltage
Three-phase 3*480VAC
350-528VAC / 50-60Hz
Input current
54Arms
82Arms
118Arms
140Arms
Output current
43Arms
85Arms
110Arms
132Arms
Maximum fuse rating per
device(=short circuit
rating)
Branch circuit protection
according to UL
80A
100A
160A
200A
JDDZ Class K5 or H
JDRX Class H
Control voltage 24VDC Compax3S and Compax3H
Controller type
Compax3
Voltage range
21 - 27VDC
Current drain of the device
0.8 A
Total current drain
0.8 A + Total load of the digital o current
for the motor holding brake
Ripple
0.5Vpp
Requirement according to safe extra
low voltage (SELV)
yes
Short-circuit proof
conditional (internally protected with 3.15AT)
Control voltage 24 VDC PSUP
Device type
PSUP
Voltage range
21 - 27VDC
Ripple
0.5Vpp
Requirement according to safe extra
low voltage (SELV)
yes (class 2 mains module)
Current drain PSUP
PSUP10: 0.2A
PSUP20 / PSUP30: 0.3A
Electric current drain Compax3M
C3M050D6: 0.85
3M100D6: 0.85A
C3M150D6: 0.85A
C3M300D6: 1.0 A
+ Total load of the digital o current for
the motor holding brake