Parker EME
Communication
192-120103 N13 C3I20T11 / C3I32T11 December 2010
305
5.4.1.3
Operating mode: Speed control
Layout of the telegram: Profibus-Master / Profinet-Controller-> Compax3
CW1
NSOLL_B(1)
Aw
n
Aw
n+2
Aw
n+4
Aw
n+6
Aw
n+8
Aw
n+10
Aw
n+12
Aw
n+14
Aw
n+16
Possible assignment:
Abbreviation
Designation
Object No.
Assigned
words
Assignment
NNOM_B
Velocity setpoint value B
(3 decimal places) *
1100.6
2
fixed
Abbreviation
Designation
Object No. Assigned
words
Assignment
CW1:
Control word 1
1100.3
1
fixed
A_DIGITAL
Digital outputs O0 ... O3
140.3
1
optional
-
Digital outputs of the M10/M12
option
133.3
1
optional
-
Demand movement speed C (1
decimal place)*
1100.8
1
optional
-
Demand movement speed D (3
decimal places)*
1100.7
2
optional
-
Setpoint acceleration A
(no decimal place)
1111.10
1
optional
-
Setpoint acceleration B
(no decimal place)
1111.3
2
optional
Setpoint deceleration
1111.16
1
optional
(only
Profinet)
Setpoint deceleration
1111.4
2
optional
(only
Profinet)
Layout of the
control word
(see on page 319).