![Parker Compax3 C3I20T11 Скачать руководство пользователя страница 266](http://html1.mh-extra.com/html/parker/compax3-c3i20t11/compax3-c3i20t11_operating-instructions-manual_3811584266.webp)
Setting
up Compax3
C3I20T11 / C3I32T11
266
192-120103 N13 C3I20T11 / C3I32T11 December 2010
(1) start frequency
This is the smallest frequency at which is still measured. During the measurement
of frequency spectrum and noise frequency response this results automatically
from the bandwidth and is only displayed as an information.
(2) End (bandwidth)
This corresponds to the highest frequency which is measured. Start frequency as
well as the frequency resolution can be varied with the aid of the bandwidth for
frequency spectrum and noise frequency response.
(3)
Frequency resolution
(see on page
During the measurement of frequency spectrum and noise frequency response
this results automatically from the bandwidth and is only displayed as an
information.
Speed control
Closed velocity control
Shows the dynamic behavior of the closed velocity control.
=> How a signal on the velocity demand value is transmitted to the velocity actual
value.
current controlled
system
position
controlled
system
actual current
actual velocity
actual
position
actual position
desired
position
Position
controller
Velocity
controller
Current
controller
TeM
Frequency
response
measurement
Signal
generator
-
-
-
f: disturbance torque
Kt
2*Pi*J
1
velocity controlled
system
Signal generator
Signal Generator
Position controller
Lageregler
actual position
Lageistwert
desired position
Lagesollwert
Velocity controller
Geschwindigkeitsregler
actual velocity
Geschwindigkeitsistwert
Current controller
Stromregler
actual current
Stromistwert
current controlled system
Stromregelstrecke
f: disturbance torque
Störmoment
velocity controlled system
Geschwindigkeitsregelstrecke
position controlled system
Lageregelstrecke
Frequency response measurement
Frequenzgangmessung