Parker EME
Communication
192-120103 N13 C3I20T11 / C3I32T11 December 2010
345
No.
Object name
Object
PNU
Bus
format
Valid
beginn
ing
681.8
Status of the actual filtered peed in the Y4
format
StatusSpeed_ActualFiltered_Y4
117
Y4
-
681.12
Filtered actual speed
StatusSpeed_ActualScaled
C4_3
-
681.13
Setpoint speed of the setpoint generator
StatusSpeed_DemandScaled
C4_3
-
681.10
Status demand speed controller input
StatusSpeed_DemandSpeedController
C4_3
-
681.4
Status demand speed of setpoint generator
StatusSpeed_DemandValue
324
C4_3
-
681.25
Negative speed limit currently effective
StatusSpeed_NegativeLimit
C4_3
-
681.24
Positive speed limit currently effective
StatusSpeed_PositiveLimit
C4_3
-
684.2
Status of motor temperature
StatusTemperature_Motor
336
I16
-
210.10
Set objects to valid
ValidParameter_Global
338.10
U16
immed
iately
1903.1
variable Column 3 Row 1
Col03_Row01
140/343.1
I16
immed
iately
684.1
Status of power output stage temperature
StatusTemperature_PowerStage
337
U16
-
685.3
Status of analog input 0
StatusVoltage_AnalogInput0
23
Y2
-
685.4
Status of analog input 1
StatusVoltage_AnalogInput1
102
Y2
-
685.1
Status of auxiliary voltage
StatusVoltage_AuxiliaryVoltage
326
E2_6
-
685.2
Status DC bus voltage
StatusVoltage_BusVoltage
327
E2_6
-
1901.1
variable Column 1 Row 1
Col01_Row01
130/341.1
Y4
immed
iately
1902.1
variable Column 2 Row 1
Col02_Row01
135/342.1
Y2
immed
iately
1904.1
variable Column 4 Row 1
Col04_Row01
145/344.1
I16
immed
iately
1905.1
variable Column 5 Row 1
Col05_Row01
150/345.1
I16
immed
iately
1906.1
variable Column 6 Row 1
Col06_Row01
155/346.1
I32
immed
iately
1907.1
variable Column 7 Row 1
Col07_Row01
160/347.1
I32
immed
iately
1908.1
variable Column 8 Row 1
Col08_Row01
165/348.1
I32
immed
iately
1909.1
variable Column 9 Row 1
Col09_Row01
170/349.1
I32
immed
iately
1910.1
Indirect table access Column 1
Indirect_Col01
181
Y4
immed
iately
1900.1
Pointer to table row
Pointer_Row
180
U16
immed
iately
1125.1
Deceleration upon error
ERROR_decel
332
U32
immed
iately
1125.2
Jerk upon Error
ERROR_jerk
333
U32
immed
iately
170.3
Filter of analog input 0
AnalogInput0_FilterCoefficient
I16
VP
171.3
Filter of analog input 1
AnalogInput1_FilterCoefficient
I16
VP
2190.2
Start current of automatic commutation
AutoCommutationControl_InitialCurrent
U16
VP
2190.4
Motion reduction Automatic commutation
AutoCommutationControl_MotionReduc
tion
U16
VP
2190.8
Reduction of the peak current
AutoCommutationControl_PeakCurrent
U16
VP
2190.3
Motion limit for automatic commutation
AutoCommutationControl_PositionThre
shold
U16
VP
2190.1
Ramp slope current slope AK
AutoCommutationControl_Ramptime
U16
VP
2190.10
Reset automatic commutation
AutoCommutationControl_Reset
U16
immed
iately
2190.7
Optimization of the standstill threshold
AutoCommutationControl_StandstillThr
eshold
U16
VP
1100.3
Control word CW
DeviceControl_Controlword_1
1
V2
immed
iately
1100.4
Control word 2
DeviceControl_Controlword_2
3
V2
immed
iately
1100.6
Device demand value A
DeviceControl_DemandValue1
Y4
immed
iately
1100.17
Demand value force
DeviceControl_DemandValue11
223
I32
immed
iately