Setting
up Compax3
C3I20T11 / C3I32T11
164
192-120103 N13 C3I20T11 / C3I32T11 December 2010
For the operating modes SINGLE, NORMAL and AUTO, the following XDIV
time settings are possible:
XDIV
Mode Scanning time Samples DIV/TOTAL
Measuring time
0.5ms
1
125us
4/40
5ms
1.0ms
2
125µs
8/80
10ms
2.0ms
3
125µs
16/160
20ms
5.0ms
4
125µs
40/400
50ms
10.0ms
5
125µs
80/800
100ms
20.0ms
6
250µs
80/800
200ms
50.0ms
7
625µs
80/800
500ms
100.0ms
8
1.25ms
80/800
1s
200.0ms
9
2.50ms
80/800
2s
500.0ms
10
6.25ms
80/800
5s
1s
11
12.50s
80/800
10s
2s
12
25.00ms
80/800
20s
5s
13
62.50ms
80/800
50s
10s
14
125.00ms
80/800
100s
For the operating ROLL, the following XDIV time settings are possible:
XDIV
Mode Scanning time Samples DIV/TOTAL
2 ms
54
125us
200/2000
2ms
54
125µs
200/2000
4ms
55
125µs
200/2000
10ms
56
125µs
200/2000
20ms
57
125µs
200/2000
40ms
58
125µs
200/2000
100ms
59
250µs
200/2000
200ms
60
625µs
200/2000
Changing the time basis is also permitted during an OSCI measuring sequence.
This means, however, that the current measurement is interrupted and started
again with the changed settings.
Settings for channels 1..4
1: Select channel color
2: Open menu for channel-specific settings