HGF Series Service Procedure
34
Figure 98
Figure 97
Figure 96
Figure 95
Install dirt and water
seal
44. Apply a small amount of clean
grease on the lip of the seal (39).
Install the seal onto the jacket
tube and input shaft/wheel tube.
See FIGURE 96.
Make final assembly
check and remove unit
from fixture
45. Make final check of the relative
groove positions on the side of the
unit using the component
alignment groove graphic on page
9B (fold-out) for comparison.
Disassemble and correct any
misassembly. Remove the four
nuts holding the unit to the fixture
and remove the unit. Make sure
shaft rotates by hand. See
FIGURE 97.
Assemble contact
brush and related parts
46. Place HGF unit on a clean
working surface. If required,
assemble spacer (51) [for 1 1/2
inch (38 mm) jacket tube only],
contact brush assembly (44)
washer (46) [for 1 3/4 inch (44
mm) jacket only] and screw and
lock washers (45). See FIGURES
98, 99, and 100. Check for the
required electrical continuity
(connection) from the horn cable
assembly (47) upper terminal to
the contact brush (44) terminal as
the input shaft/wheel tube is
rotated. There must not be any
electrical continuity (connection)
from the upper horn cable terminal
or contact brush terminal to any
other exposed part of the HGF
unit, including the body of the
contact brush.