15
HGF Series Service Procedure
Figure 25
Figure 24
Figure 23
Figure 22
27. Remove and discard the
commutator seal (19) from the
commutator cover (20). See
FIGURE 22.
Remove commutator
seal
28. Remove the eleven hex.
socket head screws (18), that
hold the metering package
together. See FIGURE 23.
Use a 3/32 inch Allen wrench.
Inspect screws for thread and
socket damage and replace as
required.
Remove cap screws
29. Lift the commutator cover (20)
from the metering package.
Remove commutator
cover
30. Inspect the ground surfaces of
the commutator cover (20).
You should notice a "normal"
polished pattern due to the
rotation of the commutator
(22). If the cover has nicks,
burrs, or scoring, it must be
replaced. See FIGURE 24.
Inspect commutator
cover
31. Remove commutator ring (21).
See FIGURE 25. Inspect for
cracks, burrs, and scoring.
Remove commutator
ring
CAUTION: Handle commutator
ring with care, as it is easily
broken.
CAUTION