HGF Series Service Procedure
Figure 28
Figure 27
Figure 26
32. Remove the commutator (22)
from the rotor (24). See
FIGURE 26.
Remove commutator
CAUTION: Five alignment pins (11)
connect the commutator to the
rotor with a slip fit. Care and
minimum force should be used to
separate the two components.
CAUTION
33. Remove the five alignment
pins (11). See FIGURE 27.
Remove alignment pins
34. Remove drive link spacer (23).
See FIGURE 28. Replace it, if
it is grooved or worn.
Remove & inspect drive
link spacer
35. The commutator (22) is made
up of two round plates pinned
and bonded together as a
permanent assembly and is
not subject to further
disassembly. Inspect the
ground surfaces of the
commutator. The holes and
edges should be free of nicks.
The ground surfaces should be
free of scoring. The edges
should be sharp.
Inspect commutator
NOTE: The commutator (22)
and commutator ring (21) are a
matched set. If either is worn
or damaged, you must replace
the set.
NOTE
36. With the rotor set (24, 25) lying
on the drive plate (26), the
rotor (24) should rotate and
orbit freely within the stator
(25). The commutator side of
the stator face must be free of
grooves or scoring.
Inspect rotor set
NOTE: The rotor (24) and
stator (25) are a matched set.
You must replace them as a
matched set, if either is worn
or damaged.
NOTE