11. Inspect the ground surfaces of
the port manifold (8). You
should notice a "normal"
polished pattern due to the
rotation of the valve plate (13)
and hex drive assembly (10).
All edges should be sharp and
free of nicks and burrs. The
surfaces of the port manifold
should be free of scratches or
scoring. If any of these wear
conditions exist, replace the
port manifold.
Inspect port
manifold
CAUTION: Many components
in the unit have finely ground
surfaces. Be careful not to
nick or scratch these surfaces.
CAUTION
12. Remove the valve ring (12),
discard the two seal rings (3).
See FIGURES 10 and 11. The
valve ring should be free of
nicks and scoring.
Remove valve ring
13. Remove the valve plate (13) by
lifting it from the isolation
manifold (15).
Remove valve plate
14. Inspect the slot edges and
ground surfaces. If the valve
plate (13) shows nicks or
scoring or the edges are not
sharp, it must be replaced.
See FIGURE 12.
Inspect valve plate
NOTE: The valve ring (12)
and valve plate (13) are a
matched set and must be
replaced as a set.
NOTE
15. Remove three springs (14)
from the isolation manifold (15)
pockets. See FIGURE 13.
Remove springs
NOTE: The unit has two
different length spring sets.
The set you have just removed
from the isolation manifold is
one-half inch (13 mm) long.
Keep this spring set separate
from the set removed from the
port manifold (8).
NOTE