11
HGF Series Service Procedure
Figure 8A
Figure 9
Figure 8
Figure 7
NOTE: The unit has two different
length spring sets. The set you have
just removed from the port manifold
are three-quarter inch (19 mm) long.
Keep this set of three springs
separate from the next set of three
springs to be removed.
10. Inspect the springs for bent or
distorted coils. If a spring is
broken or deformed, all six springs
in the unit should be replaced.
5.
Grasp the port cover (2)
assembly and lift it from the
unit. Discard three, four, or
five seal rings (4) and seal ring
(3) or if included white seal
ring (3A). See FIGURE 7.
Remove loose check ball (52)
from top of port manifold (8) if
included.
Remove port cover
6.
If included, remove the
loosened plug (6) and o-ring
(7) assembly from the port
cover. Be ready to catch the
steel check ball (5) as it falls
from its cavity. Discard o-ring
(7). See FIGURE 8.
Remove plug
6A. If included, removed the
loosened hex plug (6A) and o-
ring (7A) from the port cover
(2). Discard o-ring. Remove
relief valve cartridge (5A) and
spring (5B) assembly. A bent
or lost spring (5B) can be
serviced separately. See
FIGURE 8A. Do not try to
disassemble relief valve
cartridge (5A).
Remove hex cap &
relief valve cartridge &
spring assy.
Inspect port cover
7.
Inspect the port cover (2) for
port fitting sealing surface
scratches and thread damage.
Replace port cover, if these
conditions are evident.
NOTE
8.
Carefully lift the port manifold
(8) (3 plates bonded together)
from the unit. See FIGURE 9.
Remove springs
NOTE: Be prepared to catch
three springs (9) which may
become disengaged when
removing the port manifold.
NOTE
Remove port manifold
9.
Remove three springs (9) from
the port manifold (8).
Inspect springs
Содержание Hydraguide HGF Series
Страница 45: ...HGF Series Service Procedure Notes ...