21
HGF Series Service Procedure
Figure 48
Figure 47
Figure 46
Figure 45
Replace all seals and "O" rings with new
ones each time you assemble the HGF
unit. Be sure the seal and "O" rings
remain seated correctly when components
are assembled. See FIGURE 45.
Replace gaskets, seals
and O-Rings
NOTE: A seal kit with all required seals
except the column and jacket seal is
available for service. The seal (39) is
available separately.
NOTE
Before you reassemble the HGF, wash all
parts in clean petroleum based solvent.
Blow them dry with compressed air.
Clean and dry parts
1.
Place four bolts (40) into fixture
with shortest threaded end of bolts
through the fixture holes. Secure
bolts to fixture with four 5/16 24
UNF nuts. Tighten nuts to secure
assembly to fixture but loose
enough to turn bolts and facilitate
stacking of components. See
FIGURE 46.
Place bolts into fixture
2.
If the bushing (38) was removed
from the upper cover and jacket
tube (37) for replacement, press a
new bushing (38) into the upper
end of the jacket tube with the end
of the bushing that has recesses
toward the jacket tube. This may
be done using an arbor press or
clamping on the jacket tube per
disassembly step 52 and using the
wood handle end of a hammer.
The bushing must be seated firmly
in the jacket tube and below the
end of the jacket tube. "Crimp" the
end of the jacket tube over the
bushing in two places
approximately 90° away from the
original crimped areas, using pliers
and/or a blunt ended punch. See
FIGURES 47 and 48.
Assemble new bushing
WARNING: WEAR EYE PROTECTION
AND BE SURE TO COMPLY WITH OSHA
OR OTHER MAXIMUM AIR PRESSURE
REQUIREMENTS.
WARNING
WARNING: SINCE THEY ARE
FLAMMABLE, BE EXTREMELY
CAREFUL WHEN USING ANY SOLVENT.
EVEN A SMALL EXPLOSION OR FIRE
COULD CAUSE INJURY OR DEATH.
WARNING